Trichinella Probe-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-1408-ZJF)

Highlights

Convenient kit format with no reagent preparation—add template and run.
Target-specific probes derived from conserved DNA sequences.
Optimized for detecting trace amounts with high sensitivity.

Cat Number: STEM-SLSR-1408-ZJF

Application: For qualitative and quantitative analysis of Trichinella

Model: 22581




Description

This real-time PCR kit is designed for the sensitive and specific detection of Trichinella using probe-based technology. Primers targeting conserved gene regions of Trichinella ensure precise amplification. The generated fluorescence is continuously tracked throughout the reaction, enabling reliable qualitative and quantitative diagnostics.

Specification

Kit Components:
Trichinella Amplification Mix: 50 µL × 1 tube
Trichinella Reaction Mix: 950 µL × 1 tube
Trichinella Positive Control: 50 µL × 1 tube
Trichinella Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: Reagents in the kit are sufficient for the number of tests indicated on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light, avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
Compatible with real-time PCR systems including ABI, MX3000P/3005P, LightCycler, Bio-Rad, and Eppendorf.
Additional required equipment: DNase/RNase-free 1.5 mL centrifuge tubes, 0.2 mL PCR reaction tubes, filter tips (10 µL, 200 µL, 1000 µL), centrifuge, vortex mixer, and pipettes of various capacities.
Sample Requirements:
Depending on circumstances, use intestinal tissue from dead or culled cattle under sterile conditions. For live animals, samples may include whole blood, serum, plasma, feces, vomit, oral/nasopharyngeal/respiratory secretions, throat/nasal/ocular/anal swabs, or viral cultures.
Cross-contamination must be avoided. Samples should be tested promptly after collection or stored at -20°C ± 5°C. For long-term storage, samples should be kept below -70°C.
Sample Storage and Transport:
Short-term: Store at -20°C.
Long-term (up to 6 months): Store below -70°C.
Transport using 2-8°C ice packs. Repeated freeze-thaw cycles are strictly prohibited.

Features

Convenient kit format with no reagent preparation—add template and run.
Target-specific probes derived from conserved DNA sequences.
Optimized for detecting trace amounts with high sensitivity.
Positive control available for monitoring false negatives.
Closed-tube fluorescence detection improves workflow cleanliness.
Designed for speed in high-throughput labs.
Not for medical or diagnostic purposes.

Related Products

STEM-SLSR-1406-ZJF
STEM-SLSR-1407-ZJF
STEM-SLSR-1409-ZJF
STEM-SLSR-1410-ZJF