Human Adenovirus Type B79 Probe-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-2008-ZJF)

Highlights

Convenient kit format with no reagent preparation—add template and run.
Target-specific probes derived from conserved DNA sequences.
Optimized for detecting trace amounts with high sensitivity.

Cat Number: STEM-SLSR-2008-ZJF

Application: For qualitative and quantitative analysis of Human Adenovirus Type B79

Model: 21969

Add to Cart



Description

Optimized for molecular biology and genetic analysis, this kit applies real-time PCR technology to detect Human Adenovirus Type B79. Specific primers amplify conserved sequences of the Human Adenovirus Type B79 gene, and real-time fluorescence monitoring enables accurate assessment of gene presence and expression levels in test samples.

Specification

Kit Components:
Human Adenovirus Type B79 Amplification Mix: 50 µL × 1 tube
Human Adenovirus Type B79 Reaction Mix: 950 µL × 1 tube
Human Adenovirus Type B79 Positive Control: 50 µL × 1 tube
Human Adenovirus Type B79 Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: Reagents in the kit are sufficient for the number of tests indicated on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light, avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
Compatible with real-time PCR systems including ABI, MX3000P/3005P, LightCycler, Bio-Rad, and Eppendorf.
Additional required equipment: DNase/RNase-free 1.5 mL centrifuge tubes, 0.2 mL PCR reaction tubes, filter tips (10 µL, 200 µL, 1000 µL), centrifuge, vortex mixer, and pipettes of various capacities.
Sample Requirements:
Depending on circumstances, use intestinal tissue from dead or culled cattle under sterile conditions. For live animals, samples may include whole blood, serum, plasma, feces, vomit, oral/nasopharyngeal/respiratory secretions, throat/nasal/ocular/anal swabs, or viral cultures.
Cross-contamination must be avoided. Samples should be tested promptly after collection or stored at -20°C ± 5°C. For long-term storage, samples should be kept below -70°C.
Sample Storage and Transport:
Short-term: Store at -20°C.
Long-term (up to 6 months): Store below -70°C.
Transport using 2-8°C ice packs. Repeated freeze-thaw cycles are strictly prohibited.

Features

Convenient kit format with no reagent preparation—add template and run.
Target-specific probes derived from conserved DNA sequences.
Optimized for detecting trace amounts with high sensitivity.
Positive control available for monitoring false negatives.
Closed-tube fluorescence detection improves workflow cleanliness.
Designed for speed in high-throughput labs.
Not for medical or diagnostic purposes.

Related Products

STEM-SLSR-2006-ZJF
STEM-SLSR-2007-ZJF
STEM-SLSR-2009-ZJF
STEM-SLSR-2010-ZJF