Hemolytic Bacillus subtilis Probe-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-2504-ZJF)

Highlights

No need for additional preparation; add DNA and start.
Specific detection enabled by primers/probes based on conserved sequences.
Assay components are fine-tuned for high sensitivity.

Cat Number: STEM-SLSR-2504-ZJF

Application: For qualitative and quantitative analysis of Hemolytic Bacillus subtilis

Model: 21452




Description

This in vitro diagnostic kit employs probe-based real-time PCR for the detection of Hemolytic Bacillus subtilis nucleic acids. Designed with validated primers for conserved gene regions, the assay supports real-time fluorescence signal capture, allowing for accurate, reproducible, and quantitative molecular testing suitable for laboratory and regulatory use.

Specification

Kit Components:
Hemolytic Bacillus subtilis Amplification Mix: 50 µL × 1 tube
Hemolytic Bacillus subtilis Reaction Mix: 950 µL × 1 tube
Hemolytic Bacillus subtilis Positive Control: 50 µL × 1 tube
Hemolytic Bacillus subtilis Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: Reagents in the kit are sufficient for the number of tests indicated on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light, avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
Compatible with real-time PCR systems including ABI, MX3000P/3005P, LightCycler, Bio-Rad, and Eppendorf.
Additional required equipment: DNase/RNase-free 1.5 mL centrifuge tubes, 0.2 mL PCR reaction tubes, filter tips (10 µL, 200 µL, 1000 µL), centrifuge, vortex mixer, and pipettes of various capacities.
Sample Requirements:
Depending on circumstances, use intestinal tissue from dead or culled cattle under sterile conditions. For live animals, samples may include whole blood, serum, plasma, feces, vomit, oral/nasopharyngeal/respiratory secretions, throat/nasal/ocular/anal swabs, or viral cultures.
Cross-contamination must be avoided. Samples should be tested promptly after collection or stored at -20°C ± 5°C. For long-term storage, samples should be kept below -70°C.
Sample Storage and Transport:
Short-term: Store at -20°C.
Long-term (up to 6 months): Store below -70°C.
Transport using 2-8°C ice packs. Repeated freeze-thaw cycles are strictly prohibited.

Features

No need for additional preparation; add DNA and start.
Specific detection enabled by primers/probes based on conserved sequences.
Assay components are fine-tuned for high sensitivity.
Positive control included to verify test reliability.
Closed-system qPCR protocol helps prevent contamination.
Time-efficient workflow for quick results.
Intended solely for scientific investigations.

Related Products

STEM-SLSR-2502-ZJF
STEM-SLSR-2503-ZJF
STEM-SLSR-2505-ZJF
STEM-SLSR-2506-ZJF