Orf Virus Dye-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-0479-ZJF)

Highlights

Kit components are pre-prepared; users only supply DNA.
Primer design targets conserved elements for accurate identification.
High-performance sensitivity for trace detection.

Cat Number: STEM-SLSR-0479-ZJF

Application: For qualitative and quantitative analysis of Orf Virus

Model: 24766




Description

This kit utilizes SYBR Green dye-based real-time fluorescent PCR technology. Specific primers are designed to target highly conserved regions of the Orf Virus gene. In the presence of the target nucleic acid template, PCR amplification occurs, generating fluorescence signals. The fluorescence intensity is monitored in real time, enabling qualitative and quantitative analysis of Orf Virus with high sensitivity and specificity.

Specification

Kit Components:
Orf Virus Amplification Mix: 50 µL × 1 tube
Orf Virus Reaction Mix: 950 µL × 1 tube
Orf Virus Positive Control: 50 µL × 1 tube
Orf Virus Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: The kit components are sufficient for the number of tests specified on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light; avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
1.5 mL DNase/RNase-free centrifuge tubes
0.2 mL PCR reaction tubes
Filter tips (specifications: 10 µL, 200 µL, 1000 µL)
Centrifuge, vortex mixer, micropipettes of various specifications
Agarose, electrophoresis tank, power supply, gel imaging system
Sample Requirements:
Acceptable sample types include food, feces, vomit, oral samples, saliva, nasal/throat/eye/anal swabs, and virus cultures.
Cross-contamination should be avoided. Samples should be tested immediately after collection or stored at -20°C ± 5°C. For long-term storage, keep below -70°C.
Sample Storage and Transport:
Samples can be stored short-term at -20°C.
For long-term storage, keep below -70°C (no longer than 6 months).
During transportation, use 2-8°C ice packs. Repeated freeze-thawing is strictly prohibited.

Features

Kit components are pre-prepared; users only supply DNA.
Primer design targets conserved elements for accurate identification.
High-performance sensitivity for trace detection.
Supplied with positive control to monitor test reliability.
All reactions occur in a sealed system to reduce risk.
Suitable for research applications only.

Related Products

STEM-SLSR-0477-ZJF
STEM-SLSR-0478-ZJF
STEM-SLSR-0480-ZJF
STEM-SLSR-0481-ZJF