Human Papillomavirus Type 18 Probe-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-1896-ZJF)

Highlights

Just add DNA—kit is fully prepared for immediate use.
Primer and probe sequences selected for highly specific binding.
Maximum sensitivity supported by optimized assay design.

Cat Number: STEM-SLSR-1896-ZJF

Application: For qualitative and quantitative analysis of Human Papillomavirus Type 18

Model: 22079

Add to Cart



Description

This kit offers a robust and sensitive solution for the detection of Human Papillomavirus Type 18 using advanced real-time PCR technology. With specially designed primers targeting conserved sequences of the Human Papillomavirus Type 18 gene, the kit delivers high specificity and real-time fluorescence monitoring for accurate qualitative and quantitative analysis.

Specification

Kit Components:
Human Papillomavirus Type 18 Amplification Mix: 50 µL × 1 tube
Human Papillomavirus Type 18 Reaction Mix: 950 µL × 1 tube
Human Papillomavirus Type 18 Positive Control: 50 µL × 1 tube
Human Papillomavirus Type 18 Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: Reagents in the kit are sufficient for the number of tests indicated on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light, avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
Compatible with real-time PCR systems including ABI, MX3000P/3005P, LightCycler, Bio-Rad, and Eppendorf.
Additional required equipment: DNase/RNase-free 1.5 mL centrifuge tubes, 0.2 mL PCR reaction tubes, filter tips (10 µL, 200 µL, 1000 µL), centrifuge, vortex mixer, and pipettes of various capacities.
Sample Requirements:
Depending on circumstances, use intestinal tissue from dead or culled cattle under sterile conditions. For live animals, samples may include whole blood, serum, plasma, feces, vomit, oral/nasopharyngeal/respiratory secretions, throat/nasal/ocular/anal swabs, or viral cultures.
Cross-contamination must be avoided. Samples should be tested promptly after collection or stored at -20°C ± 5°C. For long-term storage, samples should be kept below -70°C.
Sample Storage and Transport:
Short-term: Store at -20°C.
Long-term (up to 6 months): Store below -70°C.
Transport using 2-8°C ice packs. Repeated freeze-thaw cycles are strictly prohibited.

Features

Just add DNA—kit is fully prepared for immediate use.
Primer and probe sequences selected for highly specific binding.
Maximum sensitivity supported by optimized assay design.
Positive control makes troubleshooting and verification easier.
One-tube closed operation limits contamination sources.
Ideal for quick and efficient analysis.
For investigational use only.