Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

AAnalyst 100 Atomic Absorption Spectrophotometer, Perkin Elmer (CAT#: STEM-SPO-0029-ZJF)

Highlights

Intuitive touch screen is easy-to-use, no training required
Snap-in, snap-out parts are easily replaced so there is no downtime
Rugged design can handle the toughest matrices

Cat Number: STEM-SPO-0029-ZJF

Application: For Atomic Absorption Spectrometry (AAS)

Model: AAnalyst 100

Add to Cart



Description

The manufacturer of the AAnalyst 100 Atomic Absorption Spectrophotometer, Perkin Elmer is Perkin Elmer.
Refurbished Perkin Elmer AAnalyst 100 Atomic Absorption Spectrophotometer (p/n N0400026) with AS-90plus autosampler (p/n B3140291).
Perkin Elmer AAnalyst 100 Atomic Absorption Spectrophotometer is used for flame operation and is complete with air acetylene burner head, burner chamber, six lamp turret holder, background correction & safety drain bottle.
The spectrometer measures the amount of light absorbed at a specific wavelength using a hollow cathode lamp as the primary light source, a monochromator and a detector.

Specification

Condition: Refurbished, Certified Pre-owned
Dimensions: 70 cm wide x 65 cm deep (0.46 m2) x 65 cm high
Weight: 49 kg
Power requirements: 100-230 VAC (±10%), 50/60 Hz (±1%), 300 VA (maximum)
Technical: Classified as a laboratory instrument. Complies with the applicable European Union directives and standards for safety and electromagnetic compatibility for CE Marking, the safety requirements for Canada and the United States for CSA/NRTL certification and the FCC requirements for radiofrequency emissions. The instrument was developed and produced in compliance with ISO 9001.
Environmental: Dust free, free of vibrations, ambient temperatures: +15 °C to +35 °C with a change rate of a maximum 3 °C per hour. Relative humidity: 20% to 80% noncondensing.
Optional: Perkin Elmer EDL system 2 driver (p/n N305-0064) (cat no: 03030997), PE EDL system 2 electrodless discharge lamp power supply dual lamp (p/n 0303-0835), PE N305-0014 HCL lumina lamp (CA), PE HCL lumina lamp (K).

Features

Intuitive touch screen is easy-to-use, no training required
Snap-in, snap-out parts are easily replaced so there is no downtime
Rugged design can handle the toughest matrices
PerkinElmer reliability and performance at a price that's easy-to-afford

Related Products

AA 220 FS Parts, Varian
AAnalyst 200 Atomic Absorption Spectrophotometer, Perkin Elmer
AAnalyst 300 Flame Atomic Absorption Spectrophotometer, Perkin Elmer