Streptococcus canis Probe-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-1478-ZJF)

Highlights

Convenient kit format with no reagent preparation—add template and run.
Target-specific probes derived from conserved DNA sequences.
Optimized for detecting trace amounts with high sensitivity.

Cat Number: STEM-SLSR-1478-ZJF

Application: For qualitative and quantitative analysis of Streptococcus canis

Model: 22505

Add to Cart



Description

Using high-performance probes and precision-designed primers, this real-time PCR kit enables the detection of Streptococcus canis by targeting conserved genomic regions. Fluorescence signals are emitted as the target is amplified, and the system records data in real time for confident qualitative and quantitative evaluation.

Specification

Kit Components:
Streptococcus canis Amplification Mix: 50 µL × 1 tube
Streptococcus canis Reaction Mix: 950 µL × 1 tube
Streptococcus canis Positive Control: 50 µL × 1 tube
Streptococcus canis Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: Reagents in the kit are sufficient for the number of tests indicated on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light, avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
Compatible with real-time PCR systems including ABI, MX3000P/3005P, LightCycler, Bio-Rad, and Eppendorf.
Additional required equipment: DNase/RNase-free 1.5 mL centrifuge tubes, 0.2 mL PCR reaction tubes, filter tips (10 µL, 200 µL, 1000 µL), centrifuge, vortex mixer, and pipettes of various capacities.
Sample Requirements:
Depending on circumstances, use intestinal tissue from dead or culled cattle under sterile conditions. For live animals, samples may include whole blood, serum, plasma, feces, vomit, oral/nasopharyngeal/respiratory secretions, throat/nasal/ocular/anal swabs, or viral cultures.
Cross-contamination must be avoided. Samples should be tested promptly after collection or stored at -20°C ± 5°C. For long-term storage, samples should be kept below -70°C.
Sample Storage and Transport:
Short-term: Store at -20°C.
Long-term (up to 6 months): Store below -70°C.
Transport using 2-8°C ice packs. Repeated freeze-thaw cycles are strictly prohibited.

Features

Convenient kit format with no reagent preparation—add template and run.
Target-specific probes derived from conserved DNA sequences.
Optimized for detecting trace amounts with high sensitivity.
Positive control available for monitoring false negatives.
Closed-tube fluorescence detection improves workflow cleanliness.
Designed for speed in high-throughput labs.
Not for medical or diagnostic purposes.

Related Products

STEM-SLSR-1476-ZJF
STEM-SLSR-1477-ZJF
STEM-SLSR-1479-ZJF
STEM-SLSR-1480-ZJF