Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Seahorse XFe24 Analyzer (CAT#: AM-LE-0325-Y)

Highlights

• The integrated system can report metabolic rate in minutes without sample extraction or labeling
• Wave software can control the instrument and perform real-time rate measurement to provide results on the day of measurement
• Real-time detection of the response of substrates, inhibitors and other compounds, dosing and automatic mixing through the 4 dosing port system while maintaining physiological temperature (37°C)

Cat Number: AM-LE-0325-Y

Application: • Can analyze islet function or other flowing samples<br />• Test to detect mitochondrial function<br />• Simultaneous quantitative analysis of ATP produced by glycolysis and oxidative phosphorylation<br />• A metabolic phenotype can be generated within an hour<br />• Measure the rate of glycolysis in living cells<br />• Quickly detect the dependence of cellular energy generation on mitochondrial substrates

Add to Cart



Description

Seahorse XFe24 Analyzer is manufactured by Agilent Technologies, used to determine the OCR and ECAR of live cells in 24-well plates, so as to understand the cell metabolism function of cultured cells and in vitro samples.

Specification

Number of analysis holes: 20–22
Microchamber volume: 7 µL
Plate specifications: 24-well microplate
Controller: Windows 10 computer combined with a touch screen display with complete test design, control and analysis functions.
Software: Design and run analysis templates on Wave Controller or Wave Desktop.
Main advantages:
Verify under hypoxic conditions
Verification at a detection temperature of 16–42 °C (requires a temperature below room temperature of 12–20 °C)

Features

• The integrated system can report metabolic rate in minutes without sample extraction or labeling
• Wave software can control the instrument and perform real-time rate measurement to provide results on the day of measurement
• Real-time detection of the response of substrates, inhibitors and other compounds, dosing and automatic mixing through the 4 dosing port system while maintaining physiological temperature (37°C)
• Analyze only 10,000 cells per well in a custom 24-well plate The cell number requirements vary according to cell type
• Has a precision temperature-controlled heating tray that can maintain 16-42 °C (12 °C-20 °C above room temperature), so it is compatible with a variety of samples

Related Products

Seahorse XF Imaging and Normalization System from Agilent Technologies
Seahorse XFe24 Analyzer from Agilent Technologies
Seahorse XFp Analyzer from Agilent Technologies