Highlights

Broad catalyst-retention range

Multiple polypropylene membrane grades

Adhesive-free welded construction

Cat Number: STEM-BC-2945-ZJF

Application: for catalyst removal and process-fluid clarification

Model: PP Catalyst Filtration Cartridge




Description

This polypropylene pleated cartridge is designed for catalyst removal and precision filtration of compatible liquids and gases. It uses a polypropylene microfiber membrane with polypropylene nonwoven flow-distribution layers. The media are pleated, edge sealed, enclosed by structural components, and joined through welded end caps. No adhesive is used in the assembly, and the cartridge is designed to prevent media shedding. Imported hydrophilic, imported standard, domestic high-performance, and standard domestic polypropylene membranes are available. The broad retention range supports catalyst capture, clarification, prefiltration, and final particle removal. Different production and rinsing grades support electronic, pharmaceutical, food, chemical, water-treatment, and general industrial applications. The cartridge provides broad compatibility with acids, alkalis, alcohols, ketones, dimethylformamide, phenol, and other compatible chemicals. Every completed cartridge undergoes integrity testing before release.

Specification

Membrane material: Polypropylene
Membrane options: Imported hydrophilic PP, imported PP, domestic high-performance PP, and standard domestic PP
Flow-distribution material: Polypropylene nonwoven fabric
Outer housing: Polypropylene
Inner support: Polypropylene or stainless-steel-lined polypropylene
Outside diameter: 68 or 69 mm
Inside diameter: 32 mm
Available lengths: 2.5 to 40 in
Seal options: Silicone, EPDM, NBR, FKM, and PTFE-encapsulated FKM
Filtration ratings: 0.10, 0.20, 0.45, 1.00, 3.00, 5.00, 10.0, 20.0, 40.0, and 50.0 µm
Effective filtration area: ≥0.55 m²
Compatible pH range: 1 to 14
Normal operating temperature: ≤55°C
Maximum operating temperature: 80°C at differential pressure ≤0.10 MPa
Maximum differential pressure at 25°C: 0.42 MPa forward and 0.21 MPa reverse
Endotoxin level: <0.25 EU/mL
Extractables: <0.03 g per 10 in cartridge

Features

Broad catalyst-retention range
Multiple polypropylene membrane grades
Adhesive-free welded construction
High flow with low pressure drop
Broad chemical compatibility
Low extractables
Non-shedding flow path
100% integrity testing

Related Products

STEM-BC-0007-ZJF
STEM-BC-0008-ZJF
STEM-BC-0009-ZJF
STEM-BC-0010-ZJF
STEM-BC-0011-ZJF
High-quality products

High-quality products

Reliable performance

Wide range of applications

Wide range of applications

For various laboratory needs

Expert support

Expert support

Professional service team

Fast delivery

Fast delivery

Global shipping