Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Packard Cobra Quantum 5002 Gamma Counter, Operating Temperature 60 to 95 °F, Packard Cobra (CAT#: STEM-AIAEPO-0156-LGZ)

Highlights

LCD display
Dot Matrix Printer
Fully automatic cassette-driven system

Cat Number: STEM-AIAEPO-0156-LGZ

Application: For testing in the field of biology.

Model: Quantum 5002

Add to Cart



Description

Designed for research and everyday laboratory applications, the Packard Cobra Quantum 5002 Gamma Counter is equipped with a high quality LCD display and a reliable dot matrix printer. The Cobra Quantum 5002 system also guarantees fast throughput with a fully automatic cassette drive system and high detector efficiency.

This versatile Quantum 5002 gamma counter is designed with a 2-inch Nal through-hole detector, 2000 Kev energy range, and 750 sample capacity. Additionally, the Cobra Counter 5002 is capable of counting 12x75mm RIA tubes, 16x100mm tubes and a variety of smaller microtubes with the use of available adapters. An optional instrument cart is also available.

Specification

Condition: certified pre-owned
Dimensions
Height: 28 inches (71 cm)
Width: 27 inches (69 cm)
Depth: 32 inches (81 cm)
Weight: 400 lbs (181 kg)
Electrical Requirements: 100 to 122 VAC ±10% at 50/60 Hz or 200 to 244 VAC ±10% at 50/60 Hz; 350 VA maximum
Environmental Requirements
Operating Temperature: 60 to 95 degrees Fahrenheit (°F); 15 to 35 degrees Centrigrade (°C)
Relative Humidity: 30 to 85 percent (noncondensing)
Detector: 2” thallium-activated, sodium iodide crystal
Shielding: 2 in
Energy Range: 125I Preset Region: 15 to 75 keV; 57Co Preset Region: 75 to 165 keV; 51Cr Preset Region: 240 to 400 keV; 60Co Preset Region: 1050 to 1550 keV; 75Se Preset Region: 60 to 467 keV; 131I Preset Region: 260 to 470 keV; 59Fe Preset Region: 940 to 1400 keV; 22Na Preset Region: 433 to 1417 keV; Manual Region: 15 to 2000 keV (adjustable)
Efficiency: 125I: > 72%
Background: 125I: < 50 CPM
Spilldown: 57Co into 125I preset region (at elevator position 1): < 3%
Sample Cassettes
Length: 10.48 inches
Width: 0.90 inch
Height: 2.875 inches

Features

LCD display
Dot Matrix Printer
Fully automatic cassette-driven system
2000 Kev energy range
750 sample capacity
Stat capability

Related Products

Agilent 6890N Gas Chromatograph, 28 × 31 × 16 cm, HP Agilent (CAT#-STEM-AIAEPO-0164-LGZ)
Hewlett Packard HP 5890 Series GC, Weight 90 lbs (41 kg), HP Agilent (CAT#-STEM-AIAEPO-0165-LGZ)
Hewlett Packard HP 5890 Series GC, Frequency 47.5 – 66 Hz, HP Agilent (CAT#-STEM-AIAEPO-0166-LGZ)
HP 5890 Series II Dual Detector II GC System I, HP Agilent (CAT#-STEM-AIAEPO-0167-LGZ)
HP 5890 Series II Single Detector GC System, HP Agilent (CAT#-STEM-AIAEPO-0168-LGZ)
HP 5890 Series Single Detector II GC System I, HP Agilent (CAT#-STEM-AIAEPO-0169-LGZ)