NGSmaster Microbial mNGS Automated Library Preparation Instrument (CAT#: STEM-SLSR-0007-ZJF)

Highlights

Time-saving: Automates nucleic acid extraction and library preparation in just 2 hours—significantly faster than manual methods (7-9 hours) and conventional automation systems (4-6 hours).

Space-saving: Requires only 2-3 lab zones, and can be further reduced to a single zone, optimizing lab space utilization.

Man-hours saving: Only 1-2 staff members are needed to operate the system, reducing labor requirements.

Cat Number: STEM-SLSR-0007-ZJF

Application: For automated single-cell suspension preparation with precise temperature control, suitable for temperature-sensitive tissues.

Model: NGSmaster




Description

The NGS workflow involves multiple complex steps—including nucleic acid extraction, library preparation, sequencing, and data analysis. Among them, nucleic acid extraction and library preparation are particularly time-consuming and require advanced laboratory conditions and skilled personnel.
The NGSmaster microbial mNGS automated library preparation instrument (Patent Nos. CN106404508A, CN106754339A) offers a one-stop solution that integrates nucleic acid extraction and library preparation into a fully automated process. It reduces the traditional 7-9 hours of manual work to just 2 hours, significantly improving efficiency. The system is designed to save time, space, and labor, while enhancing operational safety, flexibility, and accuracy—making it an ideal choice for clinical diagnostics, pathogen detection, and metagenomic research.

Specification

Sample Type and Minimum Sample Size:
Plasma: 200 μL
BALF: 200 μL
CSF: 1 mL
Hydrothorax and ascites: 200 μL
Sputum: 200 μL
Swab: 200 μL
Hydrarthrosis: 200 μL
Bile: 200 μL
Urine: 200 μL
Abscess fluid: 200 μL
Human aqueous: 200 μL
Marrow: 200 μL
Wound exudates: 200 μL
Other puncture fluid: 200 μL
Tissue: 10 μg
General Parameters:
Dimensions (L×W×H): 518 × 343 × 418 mm
Weight: 30 kg
Channels: 4
Library Type: DNA, RNA
Max. Multiplexing: 24 units (total 96 channels)
Ambient Temperature: 10-30°C
Minimum Nucleic Acid Input: 10 ng
Relative Humidity: 20-85% RH
Voltage: 220 V (±10%)
Temperature Control:
Heating: 20-80°C (>1.0°C/s)
Cooling: 80-20°C (>0.5°C/s)
Pipetting Range and Precision:
30-100 μL: CV < 3%
100-250 μL: CV < 2%
Management Software: NGSmaster management software v1.0.0
Consumables: Cartridge, Tip, Centrifuge

Features

Time-saving: Automates nucleic acid extraction and library preparation in just 2 hours—significantly faster than manual methods (7-9 hours) and conventional automation systems (4-6 hours).
Space-saving: Requires only 2-3 lab zones, and can be further reduced to a single zone, optimizing lab space utilization.
Man-hours saving: Only 1-2 staff members are needed to operate the system, reducing labor requirements.
Safety: Compact design allows the instrument to be placed inside a biological safety cabinet, ensuring safe operation in controlled environments.
Flexible: Features independent channels that can be scaled up to 24 units (96 channels) to meet varying throughput needs.
Precision: Independent channels minimize cross-contamination and exogenous contamination, ensuring accuracy in mNGS workflows.

Related Products

STEM-SLSR-0001-ZJF
STEM-SLSR-0002-ZJF
STEM-SLSR-0003-ZJF
STEM-SLSR-0004-ZJF
STEM-SLSR-0005-ZJF
STEM-SLSR-0006-ZJF
High-quality products

High-quality products

Reliable performance

Wide range of applications

Wide range of applications

For various laboratory needs

Expert support

Expert support

Professional service team

Fast delivery

Fast delivery

Global shipping