Mycobacterium Caprae Dye-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-0558-ZJF)

Highlights

Convenient direct-use format with only template DNA input needed.
Primer sequences selected for unmatched specificity to the analyte.
Improved detection limit due to optimized assay chemistry.

Cat Number: STEM-SLSR-0558-ZJF

Application: For qualitative and quantitative analysis of Mycobacterium Caprae

Model: 24685




Description

This kit utilizes SYBR Green dye-based real-time fluorescent PCR technology. Specific primers are designed to target highly conserved regions of the Mycobacterium Caprae gene. In the presence of the target nucleic acid template, PCR amplification occurs, generating fluorescence signals. The fluorescence intensity is monitored in real time, enabling qualitative and quantitative analysis of Mycobacterium Caprae with high sensitivity and specificity.

Specification

Kit Components:
Mycobacterium Caprae Amplification Mix: 50 µL × 1 tube
Mycobacterium Caprae Reaction Mix: 950 µL × 1 tube
Mycobacterium Caprae Positive Control: 50 µL × 1 tube
Mycobacterium Caprae Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: The kit components are sufficient for the number of tests specified on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light; avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
1.5 mL DNase/RNase-free centrifuge tubes
0.2 mL PCR reaction tubes
Filter tips (specifications: 10 µL, 200 µL, 1000 µL)
Centrifuge, vortex mixer, micropipettes of various specifications
Agarose, electrophoresis tank, power supply, gel imaging system
Sample Requirements:
Acceptable sample types include food, feces, vomit, oral samples, saliva, nasal/throat/eye/anal swabs, and virus cultures.
Cross-contamination should be avoided. Samples should be tested immediately after collection or stored at -20°C ± 5°C. For long-term storage, keep below -70°C.
Sample Storage and Transport:
Samples can be stored short-term at -20°C.
For long-term storage, keep below -70°C (no longer than 6 months).
During transportation, use 2-8°C ice packs. Repeated freeze-thawing is strictly prohibited.

Features

Convenient direct-use format with only template DNA input needed.
Primer sequences selected for unmatched specificity to the analyte.
Improved detection limit due to optimized assay chemistry.
Internal positive control enables result interpretation.
Enclosed qPCR protocol limits exposure and contamination.
Not intended for diagnostic or therapeutic use.

Related Products

STEM-SLSR-0556-ZJF
STEM-SLSR-0557-ZJF
STEM-SLSR-0559-ZJF
STEM-SLSR-0560-ZJF