Human Papillomavirus Type 6 Probe-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-1890-ZJF)

Highlights

All reagents pre-prepared; template DNA addition is the only step.
Probes and primers designed for precise recognition of target sequence.
High-sensitivity detection capability built into the system.

Cat Number: STEM-SLSR-1890-ZJF

Application: For qualitative and quantitative analysis of Human Papillomavirus Type 6

Model: 22084




Description

Using high-performance probes and precision-designed primers, this real-time PCR kit enables the detection of Human Papillomavirus Type 6 by targeting conserved genomic regions. Fluorescence signals are emitted as the target is amplified, and the system records data in real time for confident qualitative and quantitative evaluation.

Specification

Kit Components:
Human Papillomavirus Type 6 Amplification Mix: 50 µL × 1 tube
Human Papillomavirus Type 6 Reaction Mix: 950 µL × 1 tube
Human Papillomavirus Type 6 Positive Control: 50 µL × 1 tube
Human Papillomavirus Type 6 Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: Reagents in the kit are sufficient for the number of tests indicated on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light, avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
Compatible with real-time PCR systems including ABI, MX3000P/3005P, LightCycler, Bio-Rad, and Eppendorf.
Additional required equipment: DNase/RNase-free 1.5 mL centrifuge tubes, 0.2 mL PCR reaction tubes, filter tips (10 µL, 200 µL, 1000 µL), centrifuge, vortex mixer, and pipettes of various capacities.
Sample Requirements:
Depending on circumstances, use intestinal tissue from dead or culled cattle under sterile conditions. For live animals, samples may include whole blood, serum, plasma, feces, vomit, oral/nasopharyngeal/respiratory secretions, throat/nasal/ocular/anal swabs, or viral cultures.
Cross-contamination must be avoided. Samples should be tested promptly after collection or stored at -20°C ± 5°C. For long-term storage, samples should be kept below -70°C.
Sample Storage and Transport:
Short-term: Store at -20°C.
Long-term (up to 6 months): Store below -70°C.
Transport using 2-8°C ice packs. Repeated freeze-thaw cycles are strictly prohibited.

Features

All reagents pre-prepared; template DNA addition is the only step.
Probes and primers designed for precise recognition of target sequence.
High-sensitivity detection capability built into the system.
Includes positive control for experimental accuracy.
Closed-tube design reduces the chance of contamination.
Accelerated protocol supports time-saving diagnostics.
Only for use in research environments.

Related Products

STEM-SLSR-1888-ZJF
STEM-SLSR-1889-ZJF
STEM-SLSR-1891-ZJF
STEM-SLSR-1892-ZJF