Gas Chromatograph Analyzer BK-GC7820 (CAT#: STEM-OEM-0352-ZJF)

Highlights

5.7-inch LCD screen displays temperature, time, and gas flow in real time.

Features self-test, power-off protection, keyboard lock, auto ignition, and power disturbance immunity.

Internet connectivity supports data transfer and automatic program upgrades.

Cat Number: STEM-OEM-0352-ZJF

Application: For separating and analyzing gases and volatile substances in various chemical and environmental applications.

Model: BK-GC7820




Description

This gas chromatography system includes a 5.7-inch LCD display for real-time monitoring of temperature, time, and gas flow. It supports functions such as self-test, power protection, keyboard lock, automatic ignition, and anti-interference measures. It connects to the internet for automatic data transfer and upgrades. Equipped with a flame ionization detector (FID) by default, it also supports TCD, ECD, FPD, and NPD detectors, with simultaneous installation of up to three detectors. It accommodates both packed and capillary columns, offers double-column compensation to minimize noise and drift, and includes a spacious oven and powerful insulation. Comes with chromatography software for data processing.

Specification

Oven
Temperature Range: Room temperature to 450°C
Temperature Accuracy: ≤±0.1°C
Temperature Program: 16-phase programmable
Maximum Heating Rate: 40°C/min
Detector
Hydrogen Flame Ionization Detector (FID):
- Detection Limit: ≤3×10¹² g/s (Sample: n-hexadecane)
- Baseline Drift: ≤1×10⁻¹³ A/30 min
- Linear Range: ≥10⁷
Thermal Conductivity Detector (TCD) (Optional):
- Sensitivity: >10,000 mV·ml/mg (Sample: n-hexadecane)
- Linear Range: ≥10⁵
Electron Capture Detector (ECD) (Optional):
- Detection Limit: ≤1×10⁻¹⁴ g/ml (Sample: n-hexadecane δ-666)
- Linear Range: ≥10⁴
Flame Photometric Detector (FPD) (Optional):
- Detection Limit (S of thiophene): ≤2×10¹¹ g/s
- Detection Limit (P of methyl parathion): ≤1×10¹² g/s
- Linear Range (S): ≥10³
- Linear Range (P): ≥10⁴
Nitrogen and Phosphorus Detector (NPD) (Optional):
- Detection Limit (Azobenzene): ≤1×10¹² g/s
- Detection Limit (Marla sulfur phosphorous): ≤1×10¹² g/s
- Linear Range: ≥10³
Power Supply
AC 110/220V ±10%, 50/60Hz
Standard Accessories
- FID detector
- Chromatography workstation software
Optional Accessories
- Sample injection system
- TCD, ECD, FPD, and NPD detectors
- Chromatographic column
Packaging
Package Size (W×D×H): 800 × 570 × 650 mm
Gross Weight: 75 kg

Features

5.7-inch LCD screen displays temperature, time, and gas flow in real time.
Features self-test, power-off protection, keyboard lock, auto ignition, and power disturbance immunity.
Internet connectivity supports data transfer and automatic program upgrades.
Standard FID detector, with optional TCD, ECD, FPD, and NPD; supports up to three detectors simultaneously.
Compatible with both packed and capillary columns.
Dual-column compensation minimizes baseline drift and background noise.
Spacious oven (300 × 280 × 180 mm) accommodates two 0.32 mm ID capillary columns (up to 80 m each).
Excellent insulation: when oven and components are at 300°C, outer chamber remains below 40°C.
Integrated chromatography workstation software for comprehensive data analysis.

Related Products

STEM-OEM-0350-ZJF
STEM-OEM-0351-ZJF
STEM-OEM-0353-ZJF
STEM-OEM-0354-ZJF
High-quality products

High-quality products

Reliable performance

Wide range of applications

Wide range of applications

For various laboratory needs

Expert support

Expert support

Professional service team

Fast delivery

Fast delivery

Global shipping