Filter Fan Unit ECO2 manufactured by Exyte provides air filtration for non-unidirectional (turbulent) airflow cleanrooms. Combining low noise, low price and energy efficiency, the ECO2 unit is ideal for non-unidirectional (turbulent) airflow cleanrooms. Cleanroom classes ISO 3.0 to ISO 8.0 in accordance with DIN EN ISO 14644-1 can be achieved. AC and EC motors are available.
Specification
Grid size: length: 1,200 mm | width: 1,200 mm Housing length: 1,132 mm Housing width: 1,132 mm Housing height: 440 mm Weight: 45 kg Voltage: between 200 V and 277 V Phase: 1 ~ Frequency: 50 Hz / 60 Hz Rated current: between 1.8 A and 1.3 A Rated capacity: Modbus (Alu 3D): 370W | MW Bus (RadiCal): 320W | Modbus DCI (RadCial): 320W | Modbus RTU (RadiCal): 500W Number of revolutions: Modbus (Alu 3D): 296 – 1304 min-1 | MW Bus (RadiCal): 296 – 1248 min-1 | Modbus DCI (RadCial): 125 – 1250 min-1 | Modbus RTU (RadiCal): 145 – 1450min-1 Operating temperature: min.: 0 °C | max.: 40 °C Flow velocity: 0.45 m/s Air volume flow: 2,330 m³/h Differential pressure: 120 Pa Power consumption: 195 W Sound power level: pressure side: 65 dB (A) Clean room sound pressure level: 25 % occupancy: 59 dB (A) Clean room sound pressure level: 100 % occupancy: 65 dB (A) External pressure difference: Modbus (Alu 3D): 275Pa | MW Bus (RadiCal): 265Pa | Modbus DCI (RadCial): 265Pa | Modbus RTU (RadiCal): 370Pa
Accessories Particle Filter (All Filters are Filter with dry sealant. Filters with fluid sealant are available upon request.) AMC Filter for filtration of gaseous contaminants Prefilter for coarse particle filtration (Prefilter incl. Filterframing made in Aluminium) Diffusors for air distribution (Diffusor Aluminium anodized and Aluminium powder coated) Installation Frame for third Party Ceiling Systems (Filter Installation Frame Aluminium anodized and Aluminium powder coated) Cooling Coil Aerosol Measurement Connector
Features
Low noise due to optimized airflow and acoustic design Energy efficiency Easy operation Low maintenance costs Cleanroom classes D, C, B, A in accordance with EU Good Manufacturing Practice guideline Cleanroom classes 3 to 8 in accordance with ISO 14644-1 Easy installation with plug & play cable system and bearing rails Installation from plenum side optional Particle and differential pressure measurement Best performance with low price HEPA / ULPA filter classes H13 to U17 Installed radial fan balancing grade G= 2,5 according to DIN ISO 1940-1, motor with internal wired thermal contact