Dual-Peristaltic-Pump Atomic Fluorescence Spectrophotometer ASF, 206-Position Autosampler (CAT#: STEM-AL-7000-ZJF)

Highlights

Automatic Element-Lamp Identification

Pulsed Lamp Excitation And Current Monitoring

Independently Controlled Sample And Waste Pumps

Cat Number: STEM-AL-7000-ZJF

Application: for trace multi-element atomic fluorescence analysis

Model: ASF




Description

This atomic fluorescence spectrophotometer is designed for trace elemental analysis of samples that form hydrides, gaseous species, or atomic vapor. It supports determination of the listed arsenic, germanium, selenium, lead, bismuth, tellurium, tin, antimony, cadmium, zinc, mercury, and gold analytes. The instrument uses a dual-peristaltic-pump sampling system to deliver reagents and samples to the reaction and atomization path. A dual-channel optical arrangement permits simultaneous multi-element measurement and can be extended to additional channels as described in the source. Lamp identification, pulsed excitation, and channel-interference control are integrated into the measurement sequence. Gas-liquid separation and the quartz-furnace atomizer manage the reaction stream before fluorescence detection. Software functions cover instrument initialization, condition recall, measurement control, cleaning assessment, spectrum storage, and result output. Autosampler and elemental-speciation interfaces can extend the system for automated sample handling and additional analytical workflows.

Specification

Analytes As, Sb, Bi, Hg, Se, Te, Sn, Ge, Pb, Zn, Cd, And Au
Detection Limit As/Se/Pb/Bi/Sb/Te/Sn <0.01 µg/L
Detection Limit Hg/Cd <0.001 µg/L
Detection Limit Ge <0.05 µg/L
Detection Limit Zn <1.0 µg/L
Detection Limit Au <3.0 µg/L
Relative Standard Deviation <1%
Linear Range>3 Orders Of Magnitude
Inter-Channel Interference ≤±1%
Noise ≤1%
Drift ≤2%
Measurement Channels 2, Upgradable To 4
Element Lamp Inclination 45-85°
Dual Peristaltic Pumps With 10 Rollers And 2 Channels Each
Sample Measurement Time <20 s
Pump-Tube Service Life>2 Times Conventional Tubing
Four-Hour As/Sb Drift ≤2%
Carrier Fluorescence Deviation ≤10%
Detector Photomultiplier Tube With Service Life>10 Years
Autosampler Capacity 206 Positions With 200 × 10 mL Cups And 6 × 50 mL Cups
Autosampler Positioning Accuracy ±0.5 mm
Positioning Repeatability 0.3 mm
Sample Carryover <0.1%
Autosampler Configuration Standard On Fully Automatic Version

Features

Automatic Element-Lamp Identification
Pulsed Lamp Excitation And Current Monitoring
Independently Controlled Sample And Waste Pumps
Drift Compensation
Channel-Interference Suppression
Dual Gas-Liquid Separation
Quartz-Furnace Atomization
Automated Flow-Path Cleaning Assessment