Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Drager Air-Shields Isolette C2000 Infant Incubator, Dräger (CAT#: STEM-RAFAEPO-0091-ZJF)

Highlights

Provides an ideal microenvironment system for premature babies and sick infants by providing a controlled environment of warmth and humidity
Advanced Thermoregulation System: Keeps the baby in a stable environment and creates a calm zone that surrounds the neonate to inhibit convective heat loss
Dual air curtains and preemptive regulation mechanisms maintain virtually stable conditions during access to the infant

Cat Number: STEM-RAFAEPO-0091-ZJF

Application: To provide controlled environment within which an infant can be cared for and kept warm

Model: Isolette C2000

Add to Cart



Description

The manufacturer of the Drager Air-Shields Isolette C2000 Infant Incubatoris Dräger.
The Drager Air-Shield Isolette C2000 is an incubator that comes with a thermal regulation system that is used to help keep the baby in a stable environment. The incubator creates a calm zone with very low air velocity over the mattress area. The Drager Isolette C2000 makes it easy to get an x-ray of the baby without any disturbance. there is space conveniently located under the mattress where the x-ray cassette can easily slide to take x-rays. At the same time, the Air-shield Isolette puts all the critical information within your reach with a display screen that showcases the air temperature, skin temperature, heater power, oxygen, and humidity within the incubator.
The product is located in San Diego, CA, USA.

Specification

Condition: Certified Pre-owned
Dimensions
Height: 140 cm (55″)
Width: 120.6 cm (47.5″)
Depth: 75 cm (29.5″)
Weight: 95.5 kg (210 lb)
Hood Specifications
Access panel opening height: 28.0 cm (11″)
Mattress tray size: 40.6 x 81 cm (16 x 32″)
Mattress to hood height: 41.2 cm (16.25″)
Mattress size: 38.1 cm x 73.66 cm (15 in x 29″)
Mattress tilt: ±12 ° (±1 °), continuously variable
Standard hood includes:
front and rear access panel
4 access ports and 2 iris ports
3 left and 3 right tubing grommets – front
2 left and 2 right tubing grommets – rear
Cabinet Specifcations
Casters: 4 casters, 12.7 cm (5″) and 2 casters with friction brake
Storage volume: Approx. 80 l
Recessed depth: 15 cm recessed cabinet
Front loading cabinet doors: 2
Door closing mechanism: Soft-stop hinges
Opening angle of the doors: > 90°
Cabinet Stand Accessories
Gas tank mount
Shelf
IV Pole
Controller System
Algorithm type of the Servo Control System: PID (Proportional Differential Integral) control algorithm
Controller with LCD: With brightness control
Selectable color combinations: White on blue background (default) or yellow on black background
RS-232 output: Yes
Keypad lock: Yes
Temperature Control Modes
Temperature control modes: Skin and air temperature control mode
Air mode control temperature range: 20°C (68°F) to 37°C (98.6°F)
Air mode control override temp range: 37°C (98.6°F) to 39°C (102.2°F)
Skin mode control temperature range: 34°C (93.2°F) to 37°C (98.6°F)
Skin mode control override temp range: 37°C (98.6°F) to 38°C (100.4°F)
Dual-skin temperature monitoring: Yes

Features

Provides an ideal microenvironment system for premature babies and sick infants by providing a controlled environment of warmth and humidity
Advanced Thermoregulation System: Keeps the baby in a stable environment and creates a calm zone that surrounds the neonate to inhibit convective heat loss
Dual air curtains and preemptive regulation mechanisms maintain virtually stable conditions during access to the infant
With its compact design and small footprint, it fits easily in almost any NICU design, maximizing space for other equipment, caregivers, and parents

Related Products

Draeger Kappa XLT Vital Signs Engine, Dräger
Draeger MK03140-08 Regulator, Dräger
Drager ECG Cable, 5-Lead Single-Patient Use, IEC2/NEW, Dräger