Dade Dimension Xpand Clinical Chemistry System, Weight 355 kg, Dade Behring (CAT#: STEM-AIAEPO-0048-LGZ)

Highlights

Built-in automation
80 method options
Consistent dimensional platform for collaboration across test sites

Cat Number: STEM-AIAEPO-0048-LGZ

Application: For general chemical reactions, electrolytes, enzymes, therapeutic drug monitoring, toxicology, endocrinology, urine drug abuse screening, cardiac markers, tumor markers, specific proteins, immunosuppressive drugs, open channels.

Model: Dimension Xpand

Add to Cart



Description

The Dade Dimension® Xpand® Integrated Chemistry System offers small labs versatility in a compact frame. This professional analyzer has an extensive test menu and easy-to-use software to produce reliable output. The Dimension Xpand® system is suitable for a variety of laboratory settings.
Each Xpand® Chemistry System unit features innovative Dimension® Flex® kits and enhancements that make the unit ideal for incorporating lower volume clinical laboratory applications. So far, the technology has only been available on higher-capacity platforms. Dade chemical systems also combine comprehensive STAT and routine chemical testing to increase the productivity of testing programs.

Specification

Condition: certified pre-owned
Xpand®
Instrument Weight and Dimensions
Weight: 355 kg (783 lbs)
W x H x D: 129 cm X 114 cm X 79 cm (51 in. X 45 in. X 31 in.)
Power Requirement
Line Voltage: Each instrument uses a single cord; 220 Vac ± 10%, 50Hz; Single phase; 20-amp service is required for each instrument
Operating power (220 Vac): Nominal current during operation – 11 A; Maximum power – (1300W)
Host interfacing: A 25-pin female connector is required for hook-up to the male connector used for host communications port
Room Environment
Operating temperature: Room temperature must be 17 – 30˚C (65 – 85˚F) with a maximum fluctuation of 2.8˚C (5˚F) per hour. The system requires a maximum of 120 minutes to warm up from a cold start to the incubation temperature.
Relative humidity: Maintain between 20% and 80%
Average thermal output: 1100 W (3753 BTU/hr) for each instrument
Average noise output: < 70 dBA at 1m while operating
Water Consumption: 2.0 L/hr maximum throughput; Deionized water NCCLS Type 2; (HM – NCCLS Type Type 1); System is supplied with water system
Liquid waste output: 2.0 L/hr maximum throughput

Features

Built-in automation
80 method options
Consistent dimensional platform for collaboration across test sites
Simple load and run operations
Single workstation, multitasking workstation connection

Related Products

Siemens Dimension Xpand HM Chemistry Analyzer, Sample Size Max 50 μL, Siemens (CAT#-STEM-AIAEPO-0105-LGZ)
Siemens Dimension Xpand Plus Chemistry Analyzer, 110V-220V, Siemens (CAT#-STEM-AIAEPO-0106-LGZ)
Siemens Dimension Xpand Plus HM Chemistry Analyzer, Patient Sample Capacity 60, Siemens (CAT#-STEM-AIAEPO-0107-LGZ)
Siemens Dimension Xpand Plus System, 65 – 85˚F, Siemens (CAT#-STEM-AIAEPO-0108-LGZ)
Siemens/Bayer DCA 2000+ Analyzer, Weight 11.0 lb, Siemens/Bayer (CAT#-STEM-AIAEPO-0109-LGZ)
Thermo Indiko+ Chemistry Analyzer, Patient Sample Capacity 108, Thermo Scientific (CAT#-STEM-AIAEPO-0110-LGZ)