Highlights

Simplified protocol: only DNA needs to be added.
High-precision primers designed for analyte-specific detection.
Reagents optimized for robust signal sensitivity.

Cat Number: STEM-SLSR-1023-ZJF

Application: For qualitative and quantitative analysis of Canine Parvovirus

Model: 24208




Description

This kit offers a sensitive and specific method for detecting Canine Parvovirus using SYBR Green-based real-time PCR. Designed with primers targeting conserved regions, the assay produces fluorescence signals correlating with amplification levels. The real-time monitoring capability ensures accurate qualitative and quantitative results.

Specification

Kit Components:
Canine Parvovirus Amplification Mix: 50 µL × 1 tube
Canine Parvovirus Reaction Mix: 950 µL × 1 tube
Canine Parvovirus Positive Control: 50 µL × 1 tube
Canine Parvovirus Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: The kit components are sufficient for the number of tests specified on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light; avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
1.5 mL DNase/RNase-free centrifuge tubes
0.2 mL PCR reaction tubes
Filter tips (specifications: 10 µL, 200 µL, 1000 µL)
Centrifuge, vortex mixer, micropipettes of various specifications
Agarose, electrophoresis tank, power supply, gel imaging system
Sample Requirements:
Acceptable sample types include food, feces, vomit, oral samples, saliva, nasal/throat/eye/anal swabs, and virus cultures.
Cross-contamination should be avoided. Samples should be tested immediately after collection or stored at -20°C ± 5°C. For long-term storage, keep below -70°C.
Sample Storage and Transport:
Samples can be stored short-term at -20°C.
For long-term storage, keep below -70°C (no longer than 6 months).
During transportation, use 2-8°C ice packs. Repeated freeze-thawing is strictly prohibited.

Features

Simplified protocol: only DNA needs to be added.
High-precision primers designed for analyte-specific detection.
Reagents optimized for robust signal sensitivity.
Positive control supports result validation and QC.
Fully enclosed PCR setup mitigates contamination risks.
Limited to academic or laboratory research.

Related Products

STEM-SLSR-1021-ZJF
STEM-SLSR-1022-ZJF
STEM-SLSR-1024-ZJF
STEM-SLSR-1025-ZJF