Candidatus Phytoplasma Nerii Dye-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-0127-ZJF)

Highlights

No setup required—add DNA and begin.
Superior specificity derived from conserved sequence primer design.
Designed for heightened assay sensitivity.

Cat Number: STEM-SLSR-0127-ZJF

Application: For qualitative and quantitative analysis of Candidatus Phytoplasma Nerii

Model: 25123




Description

Utilizing SYBR Green real-time PCR technology, this kit is engineered for the detection and quantification of Candidatus Phytoplasma Nerii. Specific primers ensure selective amplification of the target gene. As fluorescence increases with amplification, the system provides precise and reproducible data for both qualitative and quantitative purposes.

Specification

Kit Components:
Candidatus Phytoplasma Nerii Amplification Mix: 50 µL × 1 tube
Candidatus Phytoplasma Nerii Reaction Mix: 950 µL × 1 tube
Candidatus Phytoplasma Nerii Positive Control: 50 µL × 1 tube
Candidatus Phytoplasma Nerii Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: The kit components are sufficient for the number of tests specified on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light; avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
1.5 mL DNase/RNase-free centrifuge tubes
0.2 mL PCR reaction tubes
Filter tips (specifications: 10 µL, 200 µL, 1000 µL)
Centrifuge, vortex mixer, micropipettes of various specifications
Agarose, electrophoresis tank, power supply, gel imaging system
Sample Requirements:
Acceptable sample types include food, feces, vomit, oral samples, saliva, nasal/throat/eye/anal swabs, and virus cultures.
Cross-contamination should be avoided. Samples should be tested immediately after collection or stored at -20°C ± 5°C. For long-term storage, keep below -70°C.
Sample Storage and Transport:
Samples can be stored short-term at -20°C.
For long-term storage, keep below -70°C (no longer than 6 months).
During transportation, use 2-8°C ice packs. Repeated freeze-thawing is strictly prohibited.

Features

No setup required—add DNA and begin.
Superior specificity derived from conserved sequence primer design.
Designed for heightened assay sensitivity.
Positive control ensures detection integrity.
One-tube closed system improves contamination control.
Use limited to non-clinical research.

Related Products

STEM-SLSR-0125-ZJF
STEM-SLSR-0126-ZJF
STEM-SLSR-0128-ZJF
STEM-SLSR-0129-ZJF