Beckman-Coulter AC-T Diff 5 CP, 80 Lbs In Bonney Lake, WA, USA, model AC-T Diff 5 CP, is manufactured by Beckman - Coulter general medical equipment. The Ac•T 5diff CP (Cap Pierce) hematology analyzer allows quick and direct access to a closed sample tube—a feature that reduces manual sample handling, saves time and enhances safety by eliminating operators’ exposure to biohazards.
Specification
Condition: Used Weight: 75 lbs Dimensions: 26 × 32 × 18 in Working: Working Includes: Power Cord Voltage: 120V/220V Hertz: 50Hz/60Hz Shipping type: Freight Wavelength Range: 190 to 1100 nm Wavelength Setability: 0.1 nm Increments Wavelength Accuracy -At 656.1 nm: + 0.2 nm -Full Range: + 0.5 nm Wavelength Repeatability -At 656.1 nm: + 0.1 nm -Full Range: + 0.2 nm Spectral Bandwidth (from 200 to 680 nm): < = 1.8 nm Photometric Readout: -0.300 to 3.000A or 0.0 to 200%T Photometric Accuracy (at 1A with NIST 930D solid filter at 546 nm): + 0.005A RMS Noise (at 0A, average of 10 standard deviations of 10 readings at 0.05 sec intervals, at 500 nm): < 0.0002A RMS Stray Light (measured using NaI at 220nm, per ASTM E387-84): < 0.05%T Stability(0A, constant ambient conditions, measured for one hour at 340 nm after one hour warmup): < 0.003A/hr RMS Baseline Flatness from 200 to 900 nm, at 0 A: + 0.001A RMS Scanning Speeds: 120, 240, 600, 1200, 2400 nm/min
Features
Beckman-Coulter AC-T Diff 5 CP This system offers the below features: Easy To Use, Safe Solution Closed tube sampling eliminates operators’ exposure to biohazards Two sample tube holders accommodate tubes of varying sizes, such as pediatric tubes, for increased flexibility 60 sample-per-hour throughput for streamlined workflow Comprehensive on-board Help database that uses key word searches to help solve problems quickly and easily Specially formulated reagents, controls and calibrators ensure accuracy One-step setup, operation and shutdown speeds workflow Zero daily maintenance saves time and labor Easy-To-Use Data Management Automated quality control evaluation reduces manual errors Patient storage for streamlined data recall Qualitative flagging that speeds review of patient results and decreases turnaround time 20 user-definable patient and action ranges for increased flexibility
Related Products
Beckman-Coulter AC-T Diff, 50 samples/hour In Bonney Lake, WA, USA (CAT#: STEM-CTEPO-0570-YJL) Beckman-Coulter DXH 800, 260 Lbs In Bonney Lake, WA, USA (CAT#: STEM-CTEPO-0571-YJL) Beckman-Coulter LH-755, 205 Lbs In Bonney Lake, WA, USA (CAT#: STEM-CTEPO-0572-YJL) Beckman-Coulter LH-500, 210 Lbs In Bonney Lake, WA, USA (CAT#: STEM-CTEPO-0573-YJL) Beckman-Coulter FC 500, 187 Lbs In Bonney Lake, WA, USA (CAT#: STEM-CTEPO-0574-YJL) Beckman Coulter AcT Diff 2 Hematology Analyzer, Rbc: 0.0 – 8.0 In Seattle, WA, USA (CAT#: STEM-CTEPO-0575-YJL)