Agilent 7820A GC System, Agilent Technologies (CAT#: STEM-CPO-0254-ZJF)

Highlights

Retention Time Locking (RTL) provides improved data consistency by maintaining exact retention times from injection to injection, column to column, instrument to instrument, and lab-to-lab
Electronic Pneumatics Regulation (EPR) provides the simplicity of manual operation with high-precision digital display of pressure/flow and superior ease-of-use, compared to traditional manual pneumatics systems
Great fit for routine applications using a single quadrupole mass spectrometer

Cat Number: STEM-CPO-0254-ZJF

Application: For gas chromatography

Model: Agilent 7820A

Add to Cart



Description

The manufacturer of the Agilent 7820A GC System, Agilent Technologies is Agilent Technologies.
Refurbished Agilent 7820A gas chromatograph (GC) complete with autosampler, split/splitless injector, FID detector and PC workstation.
The 7820A Gas Chromatograph system performs great day-to-day analysis. The system provides reliable capabilities for a wide range of application areas, meeting regulatory and SOP needs for small-to medium-sized labs.
Runs with full electronic pneumatic control (EPC) from inlet to detector for good retention time and area count performance. Electronic pneumatic regulation (EPR) offers manual operation simplicity with high precision digital display of pressure/flow. Superior ease-of-use over traditional systems.

Specification

Condition: Refurbished, Certified Pre-owned
Dimensions: 19 x 22 x 21 inches (49 x 56 x 51 cm)
Applications: General Purpose / Air Quality Testing / Chemical and Hydrocarbon
Processing Detection: FID / TCD / ECD / NPD
Processing Type: Packed or Capillary

Features

Retention Time Locking (RTL) provides improved data consistency by maintaining exact retention times from injection to injection, column to column, instrument to instrument, and lab-to-lab
Electronic Pneumatics Regulation (EPR) provides the simplicity of manual operation with high-precision digital display of pressure/flow and superior ease-of-use, compared to traditional manual pneumatics systems
Great fit for routine applications using a single quadrupole mass spectrometer
Single filament TCD doesn’t require a separate reference gas or manual potentiometer adjustment and provides a stable baseline without drift
Auto-ranging FID provides the ability to detect and quantitate from parts per billion (ppb) to parts per thousand in a single injectio
Other detectors include FPD plus, NPD, and µECD
Inlets options include split/splitless, packed, purge packed, and on-column inlets
Valve configurations that include up to three valves
Full electronic pneumatic control (EPC) from inlet to detector
Simplified GC front panel keys and display provide sequence information, instrument conditions,and run status, and minimize operating errors
Software keyboard and display allows the user to control the system when it connects with an integrator or 3rd-party software