Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Abbott Architect i2000 Immunology Analyzer, 200 tests/hour, Abbott (CAT#: STEM-CTEPO-0095-YJL)

Cat Number: STEM-CTEPO-0095-YJL

Application: For in vitro diagnostic use only.

Model: Architect i2000

Add to Cart



Description

Abbott Architect i2000 Immunology Analyzer, 200 tests/hour, model Architect i2000, is manufactured by Abbott. Belonging to the Architect family of Chemistry and Immunoassay systems, the Abbott Architect i2000 is a reputable and high quality Japanese designed and manufactured Chemistry Analyzer testing over 55 assays with a maximum throughput of 200 tests per hour. The system is partially an open reagent system. Immunodiagnostic testing analyzes reactions between antigens and antibodies in response to infectious disease, autoimmune disorders, immune allergies and neoplastic disease. Antigens are foreign substances which enter a patient’s body and engage the immune system to respond. These substances most typically include toxins, tumors or microorganisms such as bacteria, virus, parasite or fungi. Antibodies are proteins produced by the body’s immune system in response to an antigen. The antigen-antibody response is the natural defense against invading organisms. Most immunochemistry systems use fluorescence as its operation principle. Fluorescence is the emission of electromagnetic radiation by a substance at one wavelength after it has absorbed energy at another wavelength. This reaction takes place in the Luminometer portion of the analyzer. The 2 main methods are referred to as Fluorescence Polarization Immunoassay (FPIA) and Chemiluminescence Immunoassay (CLIA). Nephelometry and Enzyme based immunoassay are less common methods used in immunochemistry analysis. Some of the enzyme methods are referred to as: Enzyme Immunoassay (EIA), Microparticle Enzyme Immunoassay (MEIA) and Enzyme –Linked Immunosorbent Assay (ELISA). Immunodiagnostic studies are divided into two primary categories. Analysis of infectious disease are referred to as serological testing while assessment of the patient’s immune system is referred to as immune dysfunctional analysis. Some immunology instrumentation may include testing of routine chemistries or therapeutic drugs for consolidated testing. Serologic tests are classified in 4 main groups as listed. The most common tests within these groups are listed: Bacterial Tests Syphilis, Lyme, Legionnaire, Chlamydia, Streptococcal Viral Tests Mononucleosis, Epstein Barr, Rubella, Hepatitis, Rabies, HIV, Aids, Herpes Fungal Tests Histoplasmosis, Blastomycosis, Candida, Aspergillus, Cryptococcus Parasitic Tests Toxoplasmosis, Amebiasis Tests for Immune Dysfunction are used to diagnose inflammatory states, neoplastic states, nephtoric syndromes, liver disease and immune dysfunctions leading to typically, cancer. The most common tests for dysfunction are: Quantitative Immunoglobulins (IgA, IgG, IgM) Cryoglobulin Tests Collagen, Rheumatic and Connective Tissue Disease Tests Complement Components (C3,C4,C1) Antinuclear Antibody (ANA) Antiscleroderma (SCl-70) Antibody Test Total Hemolytic Complement (CH50) Anti-Smooth Muscle Antibody (ASMA) Test Antimitochondrial Antibody (AMA) Test Antiparietal Cell Antibody (APCA) Test IgE Antibody Cardiolipin Antibodies Cytoplasmic Neutrophil Antibodies (ANCA) Antisperm Antibody Test Alzheimers Disease Markers Tumor Markers

Specification

Condition: Certified Pre-Owned
Auto Sample Handling: Yes
CLIA Complexity: Moderate
Configuration: Floor Model
Depth: 112 cm (44 in)
Depth: 53 cm (21 in)
Direct Sample (STAT): Yes
Height: 122 cm (48 in)
Height: 56 cm (22 in)
Manufacturer: Abbott Diagnostics
Maximum Throughput: 200 tests/hour
Number of Assays: 23
On-Board Refrigeration: Yes
Optical System:
Luminometer
Patient Sample Capacity: 135
Point Of Care: No
Power Supply: 220V
Reagent Capacity: 25
Reagent System: Closed
Reagent Type: Liquid
Sample Cycle Time: 1740 (sec)
Sample Input Closed Tube: No
Sample Input Type:
Sample Tubes
Sample Cups
Sample Size Max: 150 μL
Sample Size Min: 15 μL
Sample Types: Plasma, Urine, Whole Blood, Serum
Series: Architect
Standby Mode: Yes
Test Method:
Chemiluminescence Detection Technology (CMIA)
Unit #2 System Control System (SCC)
Weight: 499 kg (1098 lb)
Weight: 25 kg (55 lb)
Width: 173 cm (68 in)
Width: 39 cm (15 in)

Related Products

Roche Cobas E601 Immunology Analyzer, 170 tests/hour, Roche (CAT#: STEM-CTEPO-0114-YJL)
Roche Cobas E602 Immunology Analyzer, 170 tests/hour, Roche (CAT#: STEM-CTEPO-0115-YJL)
Roche Elecsys 2010 Disk Immunology Analyzer, 86 tests/hour, Roche (CAT#: STEM-CTEPO-0116-YJL)
Roche Elecsys 2010 Rack Immunology Analyzer, 86 tests/hour, Roche (CAT#: STEM-CTEPO-0117-YJL)
Tosoh AIA-360 Immunoassay Analyzer, 36 tests/hour, TOSOH FINECHEM CORPORATION (CAT#: STEM-CTEPO-0118-YJL)
Tosoh AIA-600 Immunoassay Analyzer, 60 assays/hour, TOSOH FINECHEM CORPORATION (CAT#: STEM-CTEPO-0119-YJL)