Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

WD-9402B/D Non-medical Gene Amplification Instrument (MINIPCR), 96×0.2ml+77×0.5ml, Gradient Temperature, BEIJING LIUYI BIOTECHNOLOGY CO.,LTD (CAT#: STEM-GT-0003-YJL)

Highlights

Time increment/decrement 1~120 seconds, can do Long PCR experiment
The temperature is increased/decreased by 0.1~10.0℃, and Touchdown PCR experiment can be done
Multi-user password login to ensure user privacy and program security

Cat Number: STEM-GT-0003-YJL

Application: It can be used to do Long PCR experiments and Touchdown PCR experiments.

Model: WD-9402D

Add to Cart



Description

WD-9402B/D Non-medical Gene Amplification Instrument (MINIPCR), 96×0.2ml+77×0.5ml, Gradient Temperature, model WD-9402D, is manufactured by BEIJING LIUYI BIOTECHNOLOGY CO.,LTD. The product has programming function, the number of program storage is more than 10,000, and unlimited programs can be downloaded through U disk. The maximum number of steps is 30, and multiple nested loops can be performed.

Specification

9677 module: 96 wells×0.2ml+77 wells×0.5ml (standard)
96 module: 96 wells×0.2ml (optional)
Multi-function module: 9677 module + in-situ carrier (optional)
384 module: 384 holes (optional)
Sample stage temperature range: 0℃~100℃
Maximum heating rate: 5℃/sec
Maximum cooling rate: 4℃/sec
Sample stage temperature uniformity: ≤±0.2℃
Sample stage temperature accuracy: ≤±0.1℃
Temperature control method Analog tube and sample stage
The temperature change speed is adjustable
Hot cover temperature: 30℃~112℃ adjustable
Hot lid automatic closing function: Yes
Communication interface: USB2.0, LAN
Voltage range: Global: 85V~265V, 50-60Hz
Maximum power: 600W
Dimensions (L×W×H): 362×256×258mm
Net weight 7.4kg
Gradient temperature uniformity: ≤±0.2℃
Temperature accuracy: ≤±0.1℃
Gradient range: 30℃~99.9℃
Gradient temperature range: ≤30℃
Gradient temperature point distribution: 12 columns

Features

Time increment/decrement 1~120 seconds, can do Long PCR experiment
The temperature is increased/decreased by 0.1~10.0℃, and Touchdown PCR experiment can be done
Multi-user password login to ensure user privacy and program security
Just enter the base arrangement, automatically calculate the melting and annealing temperature, greatly improve the work efficiency Program wizard function, enter a few necessary parameters to complete the programming
With automatic pause/power-off protection
4 ℃ heat preservation, the heat preservation time is infinite

Related Products

WD-9402A Non-medical Gene Amplification Instrument (MINIPCR) (CAT#: STEM-GT-0001-YJL)
WD-9402B/D Non-medical Gene Amplification Instrument (MINIPCR) (CAT#: STEM-GT-0002-YJL)