Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Type 9A Electrical Stimulator, Yuyan Instrument Co., Ltd. (CAT#: STEM-LEAR-0717-YJL)

Highlights

Bidirectional pulse: Bidirectional pulse solves the problem of using one polar direction stimulation for a long time to produce a polar electrolytic reaction around the electrode, thus protecting the nerves, muscles, blood vessels and other tissues in contact with the electrode, and reducing the tissue polarization effect.
It solves the problem of low stimulation voltage of some biological signal acquisition and processing systems.
When the output current exceeds the current limit value, the instrument automatically reduces the pulse amplitude so that the current does not exceed the set value.

Cat Number: STEM-LEAR-0717-YJL

Application: Suit the needs of various experiments such as physiology and pharmacology

Model: 9A

Add to Cart



Description

Type 9A Electrical Stimulator, model 9A is manufactured by Yuyan Instrument Co., Ltd.
Type 9A stimulator is a multi-purpose square wave stimulator with a wide output voltage range, up to 200V, and has a current limiting protection function. The current limit is adjustable and the maximum output current is 4mA. The stimulation output is completely isolated from the control circuit, and various types of output square waves can be customized through parameter settings. The output can be triggered by a switch or an external input signal. When an external input signal is triggered, it can be set to a delayed output, and the delay time is adjustable. The output square wave includes three waveforms: positive pulse, positive pulse + delay + negative pulse, and positive pulse + negative pulse. The number of output pulses is adjustable, and the output process voltage can be adjusted at will, which can suit the needs of various experiments such as physiology and pharmacology.

Specification

Square wave output form: positive pulse
Positive pulse + delay + negative pulse
Positive pulse + negative pulse
Square wave output type:
Single wave output
Single wave intermittent output
Continuous wave output
Continuous wave intermittent output
Continuous wave transformer output
External square wave input, variable voltage and current output
Square wave parameters: Voltage: 2~200V, increments of 1V
Current: 0.01~2.00mA adjustable current limit
Increment is 0.01mA
Wave width: 50μs~4.99999s error <±2μs
Gap: 50μs~4.99999s error <±2μs
Trigger delay: 0 or 20μs~4.9999s error <±2μs
Trigger signal voltage: ±2~12V
Interruption: 1ms~999.999s
There are 8 memory settings, which can be set to the 8 most commonly used square wave output forms. With synchronous output interface.

Features

Bidirectional pulse: Bidirectional pulse solves the problem of using one polar direction stimulation for a long time to produce a polar electrolytic reaction around the electrode, thus protecting the nerves, muscles, blood vessels and other tissues in contact with the electrode, and reducing the tissue polarization effect.
It solves the problem of low stimulation voltage of some biological signal acquisition and processing systems.
When the output current exceeds the current limit value, the instrument automatically reduces the pulse amplitude so that the current does not exceed the set value.
Because the output voltage and current are adjustable, it serves as a signal amplification and waveform shaping.

Related Products

Pole Climbing Test Bench, Yuyan Instrument Co., Ltd. (CAT#: STEM-LEAR-0718-YJL)
Ladder Experimental Bench, Horizontal, Yuyan Instrument Co., Ltd. (CAT#: STEM-LEAR-0719-YJL)
Ladder Experimental Bench, Yuyan Instrument Co., Ltd. (CAT#: STEM-LEAR-0720-YJL)
Five-Hole Testing Box, Yuyan Instrument Co., Ltd. (CAT#: STEM-LEAR-0721-YJL)
Rechargeable Animal Telemetry System, Kardiotek Biomedical Technologies(Shanghai) Co., LTD. (CAT#: STEM-LEAR-0722-YJL)
Wireless Long-term Monitoring System, Kardiotek Biomedical Technologies(Shanghai) Co., LTD. (CAT#: STEM-LEAR-0723-YJL)