Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Seahorse XFe96 Analyzer (CAT#: AM-LE-0324-Y)

Highlights

• Analyze only 5000 cells per well in a custom 96-well plate The cell number requirements vary according to cell type
• Has a precision temperature-controlled heating tray that can maintain 16-42 °C (12-20 °C above room temperature), so it is compatible with a variety of samples
• Wave software can control the instrument and perform real-time rate measurement to provide results on the day of measurement

Cat Number: AM-LE-0324-Y

Application: • Test to detect mitochondrial function<br />• Determination of ATP produced by simultaneous quantitative analysis of glycolysis and oxidative phosphorylation<br />• A metabolic phenotype can be generated within an hour<br />• Determining and measuring the rate of glycolysis in living cells<br />• Detect the dependence of cellular energy production on mitochondrial substrates<br />• Analysis of three-dimensional samples such as cell spheres and islets

Add to Cart



Description

The Seahorse XFe96 Analyzer is manufactured by Agilent Technologies and can be used to determine the OCR and ECAR of live cells in 96-well plates to understand the cellular metabolic function of cultured cells and in vitro samples.

Specification

Number of analysis holes: 92
Microchamber volume: 2 µL
Plate specifications: 96-well microplate
Controller: Windows 10 computer combined with a touch screen display with complete test design, control and analysis functions.
Software: Design and run analysis templates on Wave Controller or Wave Desktop.
Main advantages:
Maximum experimental flexibility
Highest flux
Verify under hypoxic conditions
Verification at a detection temperature of 16–42 °C (requires a temperature below room temperature of 12–20 °C)

Features

• Analyze only 5000 cells per well in a custom 96-well plate The cell number requirements vary according to cell type
• Has a precision temperature-controlled heating tray that can maintain 16-42 °C (12-20 °C above room temperature), so it is compatible with a variety of samples
• Wave software can control the instrument and perform real-time rate measurement to provide results on the day of measurement
• The integrated system can report metabolic rate in minutes without sample extraction or labeling
• Real-time detection of the response of substrates, inhibitors and other compounds, dosing through the 4 dosing port system and automatic mixing, while maintaining physiological temperature (37 °C)
• The 96-well plate format can test a variety of conditions in one analysis, which is ideal for dose response studies and compound screening