Pasteurella Genus Universal Dye-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-0448-ZJF)

Highlights

Convenient direct-use format with only template DNA input needed.
Primer sequences selected for unmatched specificity to the analyte.
Improved detection limit due to optimized assay chemistry.

Cat Number: STEM-SLSR-0448-ZJF

Application: For qualitative and quantitative analysis of Pasteurella Genus Universal

Model: 24797

Add to Cart



Description

This kit offers a sensitive and specific method for detecting Pasteurella Genus Universal using SYBR Green-based real-time PCR. Designed with primers targeting conserved regions, the assay produces fluorescence signals correlating with amplification levels. The real-time monitoring capability ensures accurate qualitative and quantitative results.

Specification

Kit Components:
Pasteurella Genus Universal Amplification Mix: 50 µL × 1 tube
Pasteurella Genus Universal Reaction Mix: 950 µL × 1 tube
Pasteurella Genus Universal Positive Control: 50 µL × 1 tube
Pasteurella Genus Universal Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: The kit components are sufficient for the number of tests specified on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light; avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
1.5 mL DNase/RNase-free centrifuge tubes
0.2 mL PCR reaction tubes
Filter tips (specifications: 10 µL, 200 µL, 1000 µL)
Centrifuge, vortex mixer, micropipettes of various specifications
Agarose, electrophoresis tank, power supply, gel imaging system
Sample Requirements:
Acceptable sample types include food, feces, vomit, oral samples, saliva, nasal/throat/eye/anal swabs, and virus cultures.
Cross-contamination should be avoided. Samples should be tested immediately after collection or stored at -20°C ± 5°C. For long-term storage, keep below -70°C.
Sample Storage and Transport:
Samples can be stored short-term at -20°C.
For long-term storage, keep below -70°C (no longer than 6 months).
During transportation, use 2-8°C ice packs. Repeated freeze-thawing is strictly prohibited.

Features

Convenient direct-use format with only template DNA input needed.
Primer sequences selected for unmatched specificity to the analyte.
Improved detection limit due to optimized assay chemistry.
Internal positive control enables result interpretation.
Enclosed qPCR protocol limits exposure and contamination.
Not intended for diagnostic or therapeutic use.

Related Products

STEM-SLSR-0446-ZJF
STEM-SLSR-0447-ZJF
STEM-SLSR-0449-ZJF
STEM-SLSR-0450-ZJF