Onchocerca Americana Dye-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-0229-ZJF)

Highlights

Kit components are pre-prepared; users only supply DNA.
Primer design targets conserved elements for accurate identification.
High-performance sensitivity for trace detection.

Cat Number: STEM-SLSR-0229-ZJF

Application: For qualitative and quantitative analysis of Onchocerca Americana

Model: 25018

Add to Cart



Description

This real-time PCR kit incorporates SYBR Green dye chemistry for the detection ofOnchocerca Americana. With primers tailored to conserved gene regions, the reaction generates fluorescence during amplification. The system monitors this signal continuously, allowing users to obtain precise qualitative and quantitative data from various sample types.

Specification

Kit Components:
Onchocerca Americana Amplification Mix: 50 µL × 1 tube
Onchocerca Americana Reaction Mix: 950 µL × 1 tube
Onchocerca Americana Positive Control: 50 µL × 1 tube
Onchocerca Americana Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: The kit components are sufficient for the number of tests specified on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light; avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
1.5 mL DNase/RNase-free centrifuge tubes
0.2 mL PCR reaction tubes
Filter tips (specifications: 10 µL, 200 µL, 1000 µL)
Centrifuge, vortex mixer, micropipettes of various specifications
Agarose, electrophoresis tank, power supply, gel imaging system
Sample Requirements:
Acceptable sample types include food, feces, vomit, oral samples, saliva, nasal/throat/eye/anal swabs, and virus cultures.
Cross-contamination should be avoided. Samples should be tested immediately after collection or stored at -20°C ± 5°C. For long-term storage, keep below -70°C.
Sample Storage and Transport:
Samples can be stored short-term at -20°C.
For long-term storage, keep below -70°C (no longer than 6 months).
During transportation, use 2-8°C ice packs. Repeated freeze-thawing is strictly prohibited.

Features

Kit components are pre-prepared; users only supply DNA.
Primer design targets conserved elements for accurate identification.
High-performance sensitivity for trace detection.
Supplied with positive control to monitor test reliability.
All reactions occur in a sealed system to reduce risk.
Suitable for research applications only.

Related Products

STEM-SLSR-0227-ZJF
STEM-SLSR-0228-ZJF
STEM-SLSR-0230-ZJF
STEM-SLSR-0231-ZJF