Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

NanoString Technologies nCounter Sprint Profiler Cell Analyzer, NanoString (CAT#: STEM-CA-0550-LGZ)

Highlights

1. Fully automated and easy to use, the nCounter MAX Analysis System provides everything you need to cost effectively complete your project in record time.
2. More accurate and multiplexed than qPCR, simpler than NGS, and can digitally examine multiple pathways in a single tube in a workflow that does not require extraction, requiring only 15 minutes of human effort.
3. Spend less time on sample preparation and perform your own data analysis using the included nSolver analysis software.

Cat Number: STEM-CA-0550-LGZ

Application: For cell analysis.

Model: nCounter Sprint Profiler

Add to Cart



Description

The manufacturer of NanoString Technologies nCounter Sprint Profiler Cell Analyzer is NanoString. Model is nCounter Sprint Profiler. The nCounter® SPRINT Analyzer is designed on a single unit sized to fit on top of a laboratory bench to accelerate sample-to-data for individualized experiments. Less time can be spent on sample preparation and data analysis.

Specification

Condition: used
Level of multiplexing: Up to 800 targets

Recommended amount of starting material (dependent on assay and sample type)
RNA: 1 ng - 50 ng
DNA 5 ng - 300 ng
Protein: 250 ng - 2.5 µg
Sample types supported: Total RNA, cell lysates in GITC, FFPE-derived total RNA, and PAXgene-lysed whole blood
Reaction volume: up to 30 µg
Limit of detection 0.5 fM spike-in control: 15 zeptomole spike-in control

Fold change sensitivity
>1.5-fold (if > 5 copies per cell)
> 2-fold (if > 1 copy per cell)
Spike correlation: R² ≥ 0.95
Prep Station throughput: 12 lanes per 2.5 hours
Digital Analyzer throughput: 12 samples per 2.7 hours
Controls: Assay dependent
Operating temperature: 18–28 °C
Humidity: 30-80% (non-condensing)
Pollution degree: 2
Power source: 30-80% (non-condensing)
Power draw: 610 VA
Dimensions (Prep Station): 67 x 89 x 63 cm
Dimensions (Digital Analyzer): 66 x 66 x 48 cm
Weight (Prep Station): 120 kg
Weight (Digital Analyzer): 67 kg"

Features

1. Fully automated and easy to use, the nCounter MAX Analysis System provides everything you need to cost effectively complete your project in record time.
2. More accurate and multiplexed than qPCR, simpler than NGS, and can digitally examine multiple pathways in a single tube in a workflow that does not require extraction, requiring only 15 minutes of human effort.
3. Spend less time on sample preparation and perform your own data analysis using the included nSolver analysis software.

Related Products

BD Biosciences FacsCanto II - 3 Laser Flow Cytometer, BD Biosciences(CAT#-STEM-CA-1150-LGZ)
BD Biosciences FACSCanto II 2 Laser Flow Cytometer, BD Biosciences(CAT#-STEM-CA-1151-LGZ)
Beckman Coulter FC 500 Flow Cytometer, Beckman Coulter(CAT#-STEM-CA-1152-LGZ)
Europlasma CD600 Nanofics S/SE Nano Coating System, Europlasma(CAT#-STEM-CA-1178-LGZ)
Beckman Coulter MoFlo Astrios EQ Cell Sorter, Beckman Coulter(CAT#-STEM-CA-1252-LGZ)
Bio-Rad S3e Cell Sorter (2-Lasers) 480nm / 640nm Cell Sorter, Bio-Rad(CAT#-STEM-CA-1257-LGZ)