Mycobacterium ulcerans Probe-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-1752-ZJF)

Highlights

Ready-to-use format; users only need to provide sample DNA.
Primers and probes are designed from conserved regions for high specificity.
Optimized oligo sequences deliver excellent sensitivity.

Cat Number: STEM-SLSR-1752-ZJF

Application: For qualitative and quantitative analysis of Mycobacterium ulcerans

Model: 22223




Description

This in vitro diagnostic kit employs probe-based real-time PCR for the detection of Mycobacterium ulcerans nucleic acids. Designed with validated primers for conserved gene regions, the assay supports real-time fluorescence signal capture, allowing for accurate, reproducible, and quantitative molecular testing suitable for laboratory and regulatory use.

Specification

Kit Components:
Mycobacterium ulcerans Amplification Mix: 50 µL × 1 tube
Mycobacterium ulcerans Reaction Mix: 950 µL × 1 tube
Mycobacterium ulcerans Positive Control: 50 µL × 1 tube
Mycobacterium ulcerans Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: Reagents in the kit are sufficient for the number of tests indicated on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light, avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
Compatible with real-time PCR systems including ABI, MX3000P/3005P, LightCycler, Bio-Rad, and Eppendorf.
Additional required equipment: DNase/RNase-free 1.5 mL centrifuge tubes, 0.2 mL PCR reaction tubes, filter tips (10 µL, 200 µL, 1000 µL), centrifuge, vortex mixer, and pipettes of various capacities.
Sample Requirements:
Depending on circumstances, use intestinal tissue from dead or culled cattle under sterile conditions. For live animals, samples may include whole blood, serum, plasma, feces, vomit, oral/nasopharyngeal/respiratory secretions, throat/nasal/ocular/anal swabs, or viral cultures.
Cross-contamination must be avoided. Samples should be tested promptly after collection or stored at -20°C ± 5°C. For long-term storage, samples should be kept below -70°C.
Sample Storage and Transport:
Short-term: Store at -20°C.
Long-term (up to 6 months): Store below -70°C.
Transport using 2-8°C ice packs. Repeated freeze-thaw cycles are strictly prohibited.

Features

Ready-to-use format; users only need to provide sample DNA.
Primers and probes are designed from conserved regions for high specificity.
Optimized oligo sequences deliver excellent sensitivity.
Positive control is included to help identify false-negative results.
Closed-tube, single-step workflow minimizes contamination risk.
Fast detection with minimal processing time.
For research use only.