Mycobacterium Avium Subsp. Avium (Avian Tuberculosis) Dye-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-0566-ZJF)

Highlights

Ready-to-use kit requiring minimal preparation—just input the DNA.
High accuracy through primers tailored to conserved regions.
Excellent assay sensitivity via optimized components.

Cat Number: STEM-SLSR-0566-ZJF

Application: For qualitative and quantitative analysis of Mycobacterium Avium Subsp. Avium (Avian Tuberculosis)

Model: 24680

Add to Cart



Description

This kit offers a sensitive and specific method for detecting Mycobacterium Avium Subsp. Avium (Avian Tuberculosis) using SYBR Green-based real-time PCR. Designed with primers targeting conserved regions, the assay produces fluorescence signals correlating with amplification levels. The real-time monitoring capability ensures accurate qualitative and quantitative results.

Specification

Kit Components:
Mycobacterium Avium Subsp. Avium (Avian Tuberculosis) Amplification Mix: 50 µL × 1 tube
Mycobacterium Avium Subsp. Avium (Avian Tuberculosis) Reaction Mix: 950 µL × 1 tube
Mycobacterium Avium Subsp. Avium (Avian Tuberculosis) Positive Control: 50 µL × 1 tube
Mycobacterium Avium Subsp. Avium (Avian Tuberculosis) Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: The kit components are sufficient for the number of tests specified on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light; avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
1.5 mL DNase/RNase-free centrifuge tubes
0.2 mL PCR reaction tubes
Filter tips (specifications: 10 µL, 200 µL, 1000 µL)
Centrifuge, vortex mixer, micropipettes of various specifications
Agarose, electrophoresis tank, power supply, gel imaging system
Sample Requirements:
Acceptable sample types include food, feces, vomit, oral samples, saliva, nasal/throat/eye/anal swabs, and virus cultures.
Cross-contamination should be avoided. Samples should be tested immediately after collection or stored at -20°C ± 5°C. For long-term storage, keep below -70°C.
Sample Storage and Transport:
Samples can be stored short-term at -20°C.
For long-term storage, keep below -70°C (no longer than 6 months).
During transportation, use 2-8°C ice packs. Repeated freeze-thawing is strictly prohibited.

Features

Ready-to-use kit requiring minimal preparation—just input the DNA.
High accuracy through primers tailored to conserved regions.
Excellent assay sensitivity via optimized components.
Positive control provided to ensure analytical reliability.
Fully enclosed fluorescence PCR reaction prevents cross-contamination.
For laboratory research purposes only.

Related Products

STEM-SLSR-0564-ZJF
STEM-SLSR-0565-ZJF
STEM-SLSR-0567-ZJF
STEM-SLSR-0568-ZJF