Haemophilus Haemolyticus Dye-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-0746-ZJF)

Highlights

Ready-to-use kit requiring minimal preparation—just input the DNA.
High accuracy through primers tailored to conserved regions.
Excellent assay sensitivity via optimized components.

Cat Number: STEM-SLSR-0746-ZJF

Application: For qualitative and quantitative analysis of Haemophilus Haemolyticus

Model: 24495




Description

This kit utilizes SYBR Green dye-based real-time fluorescent PCR technology. Specific primers are designed to target highly conserved regions of the Haemophilus Haemolyticus gene. In the presence of the target nucleic acid template, PCR amplification occurs, generating fluorescence signals. The fluorescence intensity is monitored in real time, enabling qualitative and quantitative analysis of Haemophilus Haemolyticus with high sensitivity and specificity.

Specification

Kit Components:
Haemophilus Haemolyticus Amplification Mix: 50 µL × 1 tube
Haemophilus Haemolyticus Reaction Mix: 950 µL × 1 tube
Haemophilus Haemolyticus Positive Control: 50 µL × 1 tube
Haemophilus Haemolyticus Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: The kit components are sufficient for the number of tests specified on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light; avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
1.5 mL DNase/RNase-free centrifuge tubes
0.2 mL PCR reaction tubes
Filter tips (specifications: 10 µL, 200 µL, 1000 µL)
Centrifuge, vortex mixer, micropipettes of various specifications
Agarose, electrophoresis tank, power supply, gel imaging system
Sample Requirements:
Acceptable sample types include food, feces, vomit, oral samples, saliva, nasal/throat/eye/anal swabs, and virus cultures.
Cross-contamination should be avoided. Samples should be tested immediately after collection or stored at -20°C ± 5°C. For long-term storage, keep below -70°C.
Sample Storage and Transport:
Samples can be stored short-term at -20°C.
For long-term storage, keep below -70°C (no longer than 6 months).
During transportation, use 2-8°C ice packs. Repeated freeze-thawing is strictly prohibited.

Features

Ready-to-use kit requiring minimal preparation—just input the DNA.
High accuracy through primers tailored to conserved regions.
Excellent assay sensitivity via optimized components.
Positive control provided to ensure analytical reliability.
Fully enclosed fluorescence PCR reaction prevents cross-contamination.
For laboratory research purposes only.