Divergent Babesia Probe-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-2471-ZJF)

Highlights

No reagent mixing required—just input DNA to begin.
High specificity through design focused on conserved genetic loci.
Excellent signal response with optimized probes and primers.

Cat Number: STEM-SLSR-2471-ZJF

Application: For qualitative and quantitative analysis of Divergent Babesia

Model: 21486




Description

Optimized for molecular biology and genetic analysis, this kit applies real-time PCR technology to detect Divergent Babesia. Specific primers amplify conserved sequences of the Divergent Babesia gene, and real-time fluorescence monitoring enables accurate assessment of gene presence and expression levels in test samples.

Specification

Kit Components:
Divergent Babesia Amplification Mix: 50 µL × 1 tube
Divergent Babesia Reaction Mix: 950 µL × 1 tube
Divergent Babesia Positive Control: 50 µL × 1 tube
Divergent Babesia Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: Reagents in the kit are sufficient for the number of tests indicated on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light, avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
Compatible with real-time PCR systems including ABI, MX3000P/3005P, LightCycler, Bio-Rad, and Eppendorf.
Additional required equipment: DNase/RNase-free 1.5 mL centrifuge tubes, 0.2 mL PCR reaction tubes, filter tips (10 µL, 200 µL, 1000 µL), centrifuge, vortex mixer, and pipettes of various capacities.
Sample Requirements:
Depending on circumstances, use intestinal tissue from dead or culled cattle under sterile conditions. For live animals, samples may include whole blood, serum, plasma, feces, vomit, oral/nasopharyngeal/respiratory secretions, throat/nasal/ocular/anal swabs, or viral cultures.
Cross-contamination must be avoided. Samples should be tested promptly after collection or stored at -20°C ± 5°C. For long-term storage, samples should be kept below -70°C.
Sample Storage and Transport:
Short-term: Store at -20°C.
Long-term (up to 6 months): Store below -70°C.
Transport using 2-8°C ice packs. Repeated freeze-thaw cycles are strictly prohibited.

Features

No reagent mixing required—just input DNA to begin.
High specificity through design focused on conserved genetic loci.
Excellent signal response with optimized probes and primers.
Built-in positive control ensures dependable results.
Enclosed-tube qPCR minimizes environmental contamination.
Optimized for fast turnaround time.
Not approved for clinical use—research only.

Related Products

STEM-SLSR-2469-ZJF
STEM-SLSR-2470-ZJF
STEM-SLSR-2472-ZJF
STEM-SLSR-2473-ZJF