Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

DC150-1B Visual Nitrogen Blower, +5°C ~150°C, YOONING (CAT#: STEM-GLE-4093-LGZ)

Highlights

1. The heater causes the sample to be quickly heated to the evaporation temperature, and at the same time, the gas is blown to the surface of the solution through the gas needle to promote the rapid evaporation of the solution.
2. The height of the air chamber assembly is adjustable, and the slotted module is convenient to observe the liquid level of the concentrated sample.
3. Each gas needle can be controlled independently, and can be blown separately, and the flow can be adjusted separately, without wasting gas.

Cat Number: STEM-GLE-4093-LGZ

Application: Mainly used for sample concentration or preparation (such as sample preparation in drug screening, hormone analysis, liquid phase, and mass spectrometry).

Model: DC150-1B

Add to Cart



Description

The DC150-1B nitrogen blowing instrument adopts a multi-channel sample concentration device combined with a PID temperature-controlled metal bath and a nitrogen purging device. It uses high-purity aluminum material as the heat transfer medium to replace the traditional water bath device. It is easy to use and has a range of temperature control. Large, high precision features.

Specification

Temperature control range: room temperature +5°C ~150°C
Heating time: ≤ 30 min (from 20°C to 150°C)
Temperature Stability @40°C: ≤±0.3°C
Temperature Stability @100°C: ≤± 0.5°C
Temperature Stability @120°C: ≤± 1°C
General configuration module: 1 piece
Timing time setting: 0~99h59m
Nitrogen flow: 0~12L/min
Air needle length: 150mm
Air needle plate lifting stroke: 280
Nitrogen pressure: ≤0.2MPa
Maximum power: 400W
Dimensions (W×D×H): 220×290×540 (mm)

Features

1. The heater causes the sample to be quickly heated to the evaporation temperature, and at the same time, the gas is blown to the surface of the solution through the gas needle to promote the rapid evaporation of the solution.
2. The height of the air chamber assembly is adjustable, and the slotted module is convenient to observe the liquid level of the concentrated sample.
3. Each gas needle can be controlled independently, and can be blown separately, and the flow can be adjusted separately, without wasting gas.
4. When there are concentrated toxic solvents, the whole system can be placed in a fume hood.
5. Built-in over-temperature protection device, automatic fault detection and alarm function.
6. LED display, temperature synchronous display, time decrement display, simple and convenient operation. It can be set to run continuously from time to time.
7. The product has beautiful appearance, simple operation, safe and reliable use.

Related Products

DC150-1 Dry Nitrogen Blower, 1 piece, YOONING(CAT#-STEM-GLE-4096-LGZ)
DN-12A Nitrogen Blower, Room Temperature~150°C, BiLon(CAT#-STEM-GLE-4097-LGZ)
DN-24A Nitrogen Blower, Room Temperature~150°C, BiLon(CAT#-STEM-GLE-4098-LGZ)
DN-36A Nitrogen Blower, Room Temperature~150°C, BiLon(CAT#-STEM-GLE-4099-LGZ)
DN-48A Nitrogen Blower, Room Temperature~150°C, BiLon(CAT#-STEM-GLE-4100-LGZ)
DN-12W Water Bath Nitrogen Blower, Room Temperature~99°C, BiLon(CAT#-STEM-GLE-4101-LGZ)