Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Bio-Rad TC10, Total count: 6-50μm In Rocklin, CA, USA (CAT#: STEM-CAPO-0019-YJL)

Highlights

Bio-Rad TC10 Automated Cell Counter
Excellent working used condition.
Includes all pictured components only.

Cat Number: STEM-CAPO-0019-YJL

Application: Used for recombinant protein production

Model: Bio-Rad TC10

Add to Cart



Description

Bio-Rad TC10, Total count: 6-50μm In Rocklin, CA, USA, model Bio-Rad TC10, is manufactured by Bio-Rad general medical equipment.
The TC10 cell counter can count samples with or without trypan blue dye. Simply add the dye solution to the cell suspension,insert the slide, and the TC10 counter auto-detects the presence of the trypan blue dye in the sample -no user input is required.Along with the cell count, it assesses cell viability via trypan blue dye exclusion in just 30 seconds.
Using a single focal plane to assess cell viability can lead to inaccurate conclusions because of light scattering and the alignment of cells at different heights in a counting chamber. After measuring the total cell count against the best focal plane, the TC10 counter scores each cell across multiple focal planes to precisely determine if it is viable.You can get all the data you need about your cell cultures faster and easier than using a hemocytometer.

Specification

Condition: Used
Temperature Range: 4° to 100°C
Cycling Speed: 96 x 0.2 ml Reaction Module:with 20 ul sample in a 0.2 ml tube in the 96 well module.after full warm up,when cycling between 50°C and 95"C; at least 3.3"C/sec maximum heating rate and 2.0C/sec maximum cooling rate.
Storage Cooling: less than 3 minutes to cool from 40°C to 4°C
Overshoot: less than 0.5°C
Accuracy: +0.3°C to NIST traceable standard after 30 seconds at 90C block mode
Uniformity: well-to-well uniformity of +0.4°C within 30 seconds after arrival at 90°C

Features

Bio-Rad TC10 Automated Cell Counter
Excellent working used condition.
Includes all pictured components only.
100–240 V, includes reconditioned instrument only.

Related Products

Beckman Coulter Z1, 1um to 120um In New Jersey, USA (CAT#: STEM-CAPO-0004-YJL)
Beckman Coulter Z2 Cell And Particle Counter, 1 um to 120 um diameter In Ramsey, MN, USA (CAT#: STEM-CAPO-0006-YJL)
Beckman Coulter Vi-CELL XR Automated Cell Viability Analyzer, 2 µm – 70 µm In Ramsey, MN, USA (CAT#: STEM-CAPO-0010-YJL)
BECKMAN Vi-Cell XR In New Jersey, USA (CAT#: STEM-CAPO-0015-YJL)