Avian Adenovirus (Group I) Probe-Based qPCR Kit, 50 Tests/Box (CAT#: STEM-SLSR-2485-ZJF)

Highlights

Simplified operation with pre-mixed reagents requiring only DNA input.
Uses conserved region alignment to ensure high specificity.
Detects low-copy targets with high sensitivity due to optimized chemistry.

Cat Number: STEM-SLSR-2485-ZJF

Application: For qualitative and quantitative analysis of Avian Adenovirus (Group I)

Model: 21470




Description

This kit utilizes probe-based real-time fluorescent PCR technology. Specific primers are designed to target highly conserved regions of the Avian Adenovirus (Group I) gene. The system enables in vitro amplification and detection of Avian Adenovirus (Group I) nucleic acids. When the target nucleic acid is present, the PCR reaction proceeds and generates fluorescence signals. These signals are monitored in real time by the instrument to provide both qualitative and quantitative results.

Specification

Kit Components:
Avian Adenovirus (Group I) Amplification Mix: 50 µL × 1 tube
Avian Adenovirus (Group I) Reaction Mix: 950 µL × 1 tube
Avian Adenovirus (Group I) Positive Control: 50 µL × 1 tube
Avian Adenovirus (Group I) Negative Control: 50 µL × 1 tube
Instruction Manual: 1 copy
Note 1: Components from different lot numbers must not be used interchangeably.
Note 2: Reagents in the kit are sufficient for the number of tests indicated on the label.
Storage Conditions and Shelf Life:
-20°C ± 5°C, protect from light, avoid repeated freeze-thaw cycles (less than 7 times); shelf life is 12 months.
Applicable Instruments:
Compatible with real-time PCR systems including ABI, MX3000P/3005P, LightCycler, Bio-Rad, and Eppendorf.
Additional required equipment: DNase/RNase-free 1.5 mL centrifuge tubes, 0.2 mL PCR reaction tubes, filter tips (10 µL, 200 µL, 1000 µL), centrifuge, vortex mixer, and pipettes of various capacities.
Sample Requirements:
Depending on circumstances, use intestinal tissue from dead or culled cattle under sterile conditions. For live animals, samples may include whole blood, serum, plasma, feces, vomit, oral/nasopharyngeal/respiratory secretions, throat/nasal/ocular/anal swabs, or viral cultures.
Cross-contamination must be avoided. Samples should be tested promptly after collection or stored at -20°C ± 5°C. For long-term storage, samples should be kept below -70°C.
Sample Storage and Transport:
Short-term: Store at -20°C.
Long-term (up to 6 months): Store below -70°C.
Transport using 2-8°C ice packs. Repeated freeze-thaw cycles are strictly prohibited.

Features

Simplified operation with pre-mixed reagents requiring only DNA input.
Uses conserved region alignment to ensure high specificity.
Detects low-copy targets with high sensitivity due to optimized chemistry.
Contains a positive control for result validation.
Enclosed one-tube protocol limits contamination.
Fast turnaround for time-sensitive applications.
Restricted to laboratory research applications.

Related Products

STEM-SLSR-2483-ZJF
STEM-SLSR-2484-ZJF
STEM-SLSR-2486-ZJF
STEM-SLSR-2487-ZJF