Automatic Decap Centrifuge CTK120C, 4000r/min, Hunan Xiang Yi Laboratory Instrument Development Co., Ltd. (CAT#: STEM-LC-0248-YJL)

Highlights

The vacuum blood collection tube is automatically uncapped, and the success rate of uncapping is > 90%.
Suitable for two lengths of 100mm and 75mm
Touch panel, large-screen LCD display, easy to operate

Cat Number: STEM-LC-0248-YJL

Application: For blood centrifugation.

Model: CTK120C

Add to Cart



Description

Automatic Decap Centrifuge CTK120C, 4000r/min, model CTK120C is manufactured by Hunan Xiang Yi Laboratory Instrument Development Co., Ltd. When collecting blood samples, vacuum blood collection tubes are commonly used, and the tube cap must be removed manually after blood centrifugation is completed, which is inefficient. The vibration generated when the cap is removed may cause the blood to remix and increase the risk of bacterial infection. CTK120C automatic decapping centrifuges have obvious effects, which solve the problem of decapping vacuum blood collection tubes, and are ideal testing instruments.

Specification

Max speed: 4000r/min
Max RCF: 3370×g
Max capacity: 120 (ɸ13×75/100mm)
Speed accuracy: ±10r/min
Temperature setting range: 15~25℃
Temperature control accuracy: ±2℃
Compressor unit: Imported high-performance compressor unit environmentally friendly refrigerant(R134a)
Timing range: 1sec~99min59sec
Noise: ≤62dB(A)
Power supply: AC220V ±22V 50Hz
Power consumption: 1800W
Dimension: 560×660×850mm(L×W×H)
Packing dimension: 756×856×1320mm(L×W×H)
Net weight: 130kg

Features

The vacuum blood collection tube is automatically uncapped, and the success rate of uncapping is > 90%.
Suitable for two lengths of 100mm and 75mm
Touch panel, large-screen LCD display, easy to operate
Adopt AC variable frequency motor, high speed control precision, with fast speed up and down functions
Automatic calculation of RCF value
Adopt special shock absorber, good vibration reduction effect, with automatic balance function
Electronic door lock is adopted, which has strong safety performance. If the door cover is not closed properly, the centrifuge cannot start; if the door cover is opened abnormally during operation, it will automatically stop

Related Products

Automatic Decap Centrifuge CTK120R, 4000r/min (CAT#: STEM-LC-0249-YJL)
Automatic Decap Centrifuge CTK132R, 4000r/min (CAT#: STEM-LC-0250-YJL)
Automatic Decap Centrifuge CTK150R, 4000r/min (CAT#: STEM-LC-0251-YJL)
Automatic Decap Centrifuge (Frozen Type)CTK150R, 4000r/min (CAT#: STEM-LC-0252-YJL)
Automatic Decap Centrifuge CTK150, 4000r/min (CAT#: STEM-LC-0253-YJL)