Assess the Local Origin of Fish and Asparagus in Western Switzerland by Isotope Ratio Mass Spectrometry (IRMS) (CAT#: STEM-ST-0016-LJX)

Introduction

Here we present the use of isotope ratio mass spectrometry (IRMS) for the detection of mislabelling of food produced in Switzerland. The system is based on the analysis of the oxygen isotope distribution in water (δ(18)O). Depending on the location on the earth, lake or groundwater has a specific isotopic distribution, which can serve as a fingerprint in order to verify whether a product has grown by means of the corresponding water. The service used IRMS technology to detect the local origin of fish growing in Swiss lakes and asparagus grown in the Canton of Valais.




Principle

Isotope ratio mass spectrometry (IRMS) leverages magnetic sector mass spectrometry to enable high-precision measurement of the stable isotope content of a sample. Typical measurements target hydrogen, carbon, nitrogen, and oxygen analyses—although elements with masses up to and including sulfur can be measured. Solid, liquid, or gas phase samples are converted to simple gases then introduced to the IRMS. During analysis, an electron impact source ionizes sample-derived gas which is then accelerated down a flight tube, separated by mass, and quantified using a series of Faraday cups. The high precision of IRMS enables enumeration of even very small isotopic fractionation associated with physical, chemical, and biological transformations or natural abundance measurements.

Applications

For explaining the detailed molecular mechanisms behind biological processes
For understanding and quantifying nutrient and material exchanges between ecosystems
For providing ultra-precise stable isotope analyses
For understanding the geological history of the Earth
For food authenticity, forensic science, medical research and anti-doping testing

Procedure

1. Fill the reaction tube and install it, connect the gas path
2. Check for helium leaks
3. Heat up the reactor, wait for the reaction tube to burn stable, adjust the state of the equipment
4. Wrap the sample in a tin cup and test the sample
5. Store and process data

Materials

• Sample Type:
Fish and asparagus in Western Switzerland

Notes

1.The approach is also valuable for quantifying the reactivity and progression of an applied stable isotope tracer to help determine reaction rates and final disposition of applied substrates.
2.IRMS offers a way of measuring isotopic variations with extremely high levels of accuracy. It can be used to detect isotope values of lighter elements with no issues, making it instrumental in the analysis of organic and natural samples.